READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
SETTING THE FILL LEVEL
1. Place the jerry can / User-pack in the AFS-1E/AFS-1E-UPB with
the neck/cap next to the chemical hose.
2. Note the appropriate fill height for the can / User-Pack.
3. Loosen the CGRP14K cord grip and slide the bottom of the level
sensor tube 1 inch (25mm) below the desired fill level. NOTE:
The LST14 level sensing tube shuts off the system when it detects
back pressure. The end of the tube must be submerged before
generating back pressure.
4. Retighten the CGRP14K cord grip with a wrench.
5. Set the Level Sensing regulator (Left gauge) between 0.5 to 2
PSI. Turn the dial below the gauge counterclockwise to increase
pressure.
6. Test the system by filling the can / User-Pack with water.
NOTE: The system will consistently fill the same can / User-Pack
to this preset level.
7. Perform a test with the chemical to ensure that the LST14 level
sensing tube is calibrated correctly with the chemical.
OPERATION INSTRUCTIONS
Always wear the appropriate personal protective equipment (PPE) when
operating the AFS-1E/AFS-1E-UPB.
1. Use the handle to guide the fill tube into the can / User-Pack
opening and place designated can / User-Pack on to rack.
2. Ensure that can / User-Pack is properly located on the rack. The
can / User-Pack must push down on the whisker valve to activate
the system.
3. Close the door and secure the latch.
4. Turn the black "Power" switch to the " I " position and the
system will be ready to be activated.
5. Press the green "Start" button to fill the can / User-Pack to the
designated level. The system will shut off automatically at the
designated fill level.
6. The red "E-Stop" button can be used to shut off the system
immediately if necessary.
7. Turn the black "Power" switch to the " O " position.
8. Open the door. Hold the handle of the fill tube while gently
removing the can / User-Pack from the rack.
9. Due to chemical residue left on fill tube, avoid touching the fill
tube.
NOTICE:
• If the door is opened while the system is filling, the system will
shut off.
• The system will not turn on unless a can / User-Pack is properly
positioned on the rack.
• if a can / User-Pack is placed with a liquid level that is higher
than the set fill level, the unit will not activated when the "Start"
button is pushed.
• It is recommended to rinse the system thoroughly with water
once a week.
Manufactured Year: 2019 | Model Number: AFS-1E, AFS-1E-UPB
Manufactured by: FOAM-iT
3833 Soundtech Ct. Grand Rapids, MI 49512 US
REPLACE EMPTY CHEMICAL SUPPLY
Always wear the appropriate personal protective equipment (PPE) when
operating the AFS-1E/AFS-1E-UPB.
1. Make sure power is in " O " position.
2. Close HV60 ball valve.
3. Remove suction lance from empty chemical supply and place
in full chemical supply. NOTICE: Avoid coming to contact with
chemical.
4. Correctly position full chemical supply .
5. Open HV60 ball valve.
TO CHANGE CHEMICAL PRODUCT
Always wear the appropriate personal protective equipment when
changing chemical product.
NOTE: It is not recommended to change product. The machine is
intended to be use with one product only. In case of product change
follow below instructions.
1. Remove the suction lance from the chemical supply.
2. Using a suitable can / User-Pack, rinse the system thoroughly
with water.
3. Place the suction lance in the new chemical drum.
4. Cycle the system until any remaining water is flushed out and
only the chosen chemical is dispensed.
5. Verify the fill level is correct.
Maintenance
Always wear appropriate personal protective equipment (PPE) when
servicing unit. There may be chemical in the system. Flush the system
with sufficient water to clear out remaining chemicals.
Practice proper Preventive Maintenance:
• Rinse and clean drip pan weekly.
• Replace the H12B and H12CB hose every 6 months if the
chemical being transferred contains one or more of the
following ingredients:
NaOH
KOH
H2O2
HNO3
H2SO4
Acetic acid
Peracetic acid
Peroxyoctanoic acid
Surfactants
Please see the Product Data Sheet from your chemical supplier
to identify ingredients in product or ask your Ecolab application
specialist.