2 If the batteries are supplied without liquid (i.e. dry), they must be filled with sulphuric acid (density from 1.27 to 1.29 kg
at 25° C), according to the instructions given in th e next paragraph and in the battery handbook:
Filling batteries with acid.
Pay particular attention when you are handling sulphuric acid. This substance is corrosive. If it comes into
contact with your skin or eyes, wash with plenty of fresh water and seek medical assistance.
Batteries must be filled in a ventilated area.
Fill the cells (or single elements) of the batteries with acid. The correct level is indicated in the battery instruction
handbooks.
After an hour, top up the cells, if necessary, with more acid.
Let the batteries rest – with the machine stopped – for another hour and then refill, in accordance to the
instructions given in the handbook provided with the battery (refer to the "MAINTENANCE" section). During the
charging operations, all battery caps must be open.
3 If the machine has been supplied without batteries, these must be purchased and installed accordingly.
Competent battery specialists should preferably be contacted to choose and install the new
batteries.
The electrical connection cables supplied with the machine may be used to connect the
batteries.
Once the batteries have been installed, connect the battery connector to the machine.
If the machine is in the DP version, it must be filled with lead-free petrol, depending on the
engine. A label indicating the kind of fuel to use is in any case applied near the fuel cap.Check
the level of oil in the engine
Get onto the machine and adjust the height of the seat to your convenience.
The machine is now ready for use.
When removing the batteries, the operator must be equipped with suitable personal protection devices (gloves, goggles,
overalls, safety shoes, etc) to reduce the risk of accidents. Make sure the switches on the control panel are in the "0"
position (off) and the machine is turned off. Keep away from naked flames, do not short circuit the battery poles, do not
cause sparks and do not smoke. Proceed as follows.
•
disconnect the battery wiring and bridge terminals from the battery poles.
•
if necessary, remove the devices fixing the battery to the base of the machine.
ENGLISH (
Translation of original instructions)
REMOVING THE BATTERIES
4