Setting the free
motion of the
slide
Safety chain
Starting to work
Switching on the
stand
Switching on the
magnet
Switching on the
machine
Switching off
Switching off the
machine
Switching off the
magnet
ENGLISH
Always disconnect the plug from the socket before carrying out any work on the
machine.
The carriage is adjusted by the factory
such that it will stop in any position and not
move down by the weight of the machine.
In case that the carriage play must be
adjusted, proceed as follows:
Loosen the locking nuts with fork wrench
SW8, adjust the carriage play with Allen
key size 2.5, and re–tighten the locking
nuts.
Secure the magnetic drill stand with the provided chain when working slanting or
vertical surfaces, or overhead such that it won't fall down in case of power loss.
The safety chain must be applied such that the drill stand will move away from the
user in case of power loss.
For optimum operating safety the magnetic drill stand is equipped with a main switch.
MDE 1200 is also equipped with a temperature–controlled overload protection.
Depress the black push button. The red
control light will turn on.
It is possible to press the other buttons.
Depress the yellow push–button for
magnetic field to build up. The yellow
control light is on.
Depress the green push–button. The
green controlwill come and the drill will
start.
Depress the green push–button. The drill
will turn off..
Depress the yellow push–button. A long
signal tone is audible. The magnetic field
dies away after approx. 3 seconds.