Checks And Adjustments - Sima SPIRAL-26 Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. CHECKS AND ADJUSTMENTS

FIGURE 15
No
LEFT/ STOP/ RIGHT Ensures the machine to rotate to the right or left
1
2
MAN/ AUTO
3
4
POWER LED
5
6
EMERGENCY STOP
7
MAIN SWITCH
8
POWER PANEL
8.1 Adjustment of thermal current field, and motor circuit breaker
It is ex-works adjusted by its manufacturer as 8.6 A for 1.5 -2.5 kW motor with 750 -1.500 rpm.
(Figure 15) Do not change this adjustment. The motor circuit breaker is installed onto the
machine to de-energize the motor in order the machine not to be damaged when it takes
excessive current. Turn the switch to the position (1) for re-starting the machine in case of
circuit breaking. Under no circumstances the circuit breaker is dismantled.
Note: Should the machine be stopped by pressing the emergency stop knob turn the
MAN/AUTO switch to the MAN position and the LEFT/STOP/RIGHT switch to the reverse of
direction in that moment, and then to the direction of arrow the Emergency Stop, and press the
foot pedal and pull the material compressed out of the machine.
BUTTON
direction.
ON
Ensures the machine to be started.
Ensures the machine to be controlled automatically or
manually.
OFF
Ensures the machine to be stopped.
Indicates the power in the system is on when the
button (ON) is pressed on.
Provides the machine to be stopped in emergency by
disconnecting the power.
It is such a toggle switch ensuring the power input for
the machine (0 means the machine is off, and 1 is on.)
It is such a component ensuring and controlling power
to be supplied for the machine.
FUNCTION
9

Publicidad

Tabla de contenido
loading

Tabla de contenido