Dometic FreshWell2000 Instrucciones De Uso página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Technical description
6.1
Components
The refrigerant circuit of the under-bench air conditioner consists of the
following main components (fig. 1, page 3):
z Compressor (1)
The compressor draws in the refrigerant used and compresses it. This
raises the pressure and therefore the temperature of the refrigerant.
z Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flow-
ing past absorbs the heat and the hot refrigerant gas cools down and
becomes liquid.
z Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them.
The refrigerant absorbs the heat and vaporises.
z Blower (4)
A blower distributes the cooled or heated air within the vehicle through
an air outlet unit.
12
FreshWell2000
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido