Wc version, close the water circuit with the dryer stopped.
5 Control
(PSE120-180)

5.1 Control panel

Fig.1
1
2
3
1
2
I
QS
O
QS Main power switch.
UP button: press to increment the value of a selected
editable parameter.
DOWN button: press to decrement the value of a selected
editable parameter.
esc
ESC button : to exit without saving;
returns to the previous level;
PRESSED FOR 5s. ALARM RESET.
set
SET button : to exit and saving/ confi rm the value;
go to the next level;
enter on Set Menu;
PRESSED FOR 5s. START DRYER.
esc
set
and
.
: press together ro enter on the parameters of the
program
English
5.2 Symbol
Symbol
Symbol status
Function
k
Lit up
compressor ON
Off
compressor OFF
Lit up
dryer ON
FLashing
dryer OFF
Lit up
Alarm present
!
FLashing
Warning present
Off
No alarm present
q
Lit up
Condensate drain ON
Off
Condensate drain OFF

5.3 Parameter settings

Temperature measurement unit
How to set the temperature measurement unit.
esc
set
Press the buttons
and
together to enter on general
menu "PAr" .
set
to enter on menu " CF9"
Press
set
to enter on the parameter " C_F".
Press
set
Press
to choose:
ON : Fahrenheit;
OFF: Celsius.
set
Press
to confi rm.
esc
Press
to exit.
esc
set
PAr
esc
set
CF9
esc
set
C_F
set
esc
On
OFF
PSE 120-350
5.4 Confi guration condensate drain
There are three modes of operation:
a) CAPACITIVE = Automatic drainign using a capacitive sensor;
b) TIMED = programmable draining times;
c) CONTINUOUS (external) = if there is an external drain.
set
Press the button
to enter on menu of the direct parameters.
to fi nd the menu " Cd "
Use the arrows
or
set
Press
to enter.
to fi nd the parameter " d3 "
Use the arrows
or
set
Press
to choose the type of the drain:
0 = capacitive;
1 = timed;
2 = external.
set
Press
for fi ve seconds to select the drain.
set
Al
HiSt
d2
d3
set
esc
1
0
For the option (1) timed drain,it is possible to set the ON/OFF time of
the drain.
On menu " Cd "
Use the arrows
or
to fi nd the parameter "d1" to chose the
opening time.
set
Press
to confi rm.
to fi nd the parameter " d2 " to choose
Use the arrows
or
the closed time.
set
Press
to confi rm.
esc
Press
to exit.
Cd
set
esc
d1
2
3/12