LaserLiner ThermoVisualizer Manual De Instrucciones página 18

Ocultar thumbs Ver también para ThermoVisualizer:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
9
General settings: Time Stamp
With the timestamp active, the date and time of the recording will be added to the saved digital image.
Main Menu
E: 0.95
HAL Temp: 250°C
LAL Temp: -20°C
Auto off: 1 min
Backlight
Date / Time
Time Stamp
Erase file
Save File as
Noise Filter
1/2
Measurement-specific settings
Before each use, check the settings for infrared measurement and adjust them to the respective measuring
situation to ensure accurate measurements. Pay particular attention to the general parameters for the
emissivity coefficient.
10
Measurement-specific settings: Emissivity coefficient
The level of infrared emissions given off by everything depends on the specific material and surface. This
factor is determined by the emissivity coefficient (0.10 ... 1.0). For accurate measurements, it is absolutely
essential that the emissivity coefficient is set first. The emissivity coefficient can either be custom set or
selected based on the predefined emissivity coefficients from the material list.
To set individual emissivity
Main Menu
E: 0.95
HAL Temp: 250°C
LAL Temp: -20°C
Auto off: 1 min
Backlight
Date / Time
Time Stamp
Erase file
Save File as
Noise Filter
1/2
18
GB
Time Stamp
Settings
Stamp ON
Stamp OFF
Back to Menu
Emissivity
Settings
Black body: 1
Matt: 0.95
SemiMatt: 0.8
SemiGlossy: 0.6
Glossy: 0.3
Set E value
Back to Menu
ON
OFF
Emissivity
Settings
Black body: 1
Matt: 0.95
SemiMatt: 0.8
SemiGlossy: 0.6
Glossy: 0.3
Set E value
Back to Menu
e=0.95
Increase value
Decrease value

Publicidad

Tabla de contenido
loading

Tabla de contenido