instruction manual
instAllAtion -
feet
The two support feet must be fitted by using the screws, before you use
the convector heater. Please see figure 2.
instAllAtion -
suspension bracket
If you wish to hang the frost protector from a wall, the suspension bracket must first be attached to the wall
(see figure 3).
1. Indicate on the wall where you wish to attach the bracket. Make sure the frost protector will hang
horizontally.
2. Drill two holes in the wall at the marked locations. Make sure the holes are big enough to fit the screw
plugs.
3. Push the plugs into the holes.
4. Use the screws to attach the suspension bracket to the wall and, if necessary, adjust it horizontally.
5. Slide the frost protector down onto the suspension bracket.
6. Screw the suspension bracket to the side of appliance.
When hanging the frost protector from a wall, make sure there is enough free space around the frost
protector. There should be the following amount of free space:
- At the top 70 cm
- At the bottom 60 cm
- At the sides 40 cm
use
1. Rotate the thermostat dial to the left.
2. Insert the plug into the plug socket.
3. Rotate the thermostat dial to the right. The appliance will turn itself on, a click will be heard and the
indicator light will be lit .
4. Once the desired temperature has been reached, the appliance will turn off automatically. A click will be
heard and the indicator light will go out.
To find the ideal thermostat setting, rotate the thermostat dial clockwise as far as possible. Once the
room has reached the desired temperature, slowly rotate the dial anticlockwise until a click is heard.
The appliance will then turn itself off. The temperature regulator will ensure that the room remains at
the set temperature.
The frost protector is fitted with an overheating safeguard. If the temperature in the appliance gets too
high, the heating element will turn off automatically. The overheating safeguard will be disabled once
the appliance has cooled down sufficiently and the frost protector can then be used again.
20
Figure 2
Figure 3