User interface

1 Activated: solar collector temperature suffi cient for
exchange, normal operation
Flashing: solar collector cold recognition function
2 Activated: solar collector antifreeze function
3 Activated: shutter closed for reaching of hot water tank
max. temperature
Deactivated: shutter open, normal operation
4 Activated: solar collector temperature ok, normal ope-
ration
Flashing: solar collector cooling function
5 Solar circulating pump operation
6 Flow-rate limiter adjustment mode
7 Flow-rate limiter adjustment mode
8 Solar card fault
11 Upper hot water tank / solar collector return temperatu-
re
12 Hot water tank / solar collector temperature
13 Activated: solar collector temperature sensor ok, nor-
mal operation
Deactivated: solar collector temperature sensor fault
Flashing: solar collector limit temperature function
14 Activated: solar collector return temperature sensor
ok, normal operation
Deactivated: solar collector return temperature sensor
fault
15 Activated: boiler hot water tank temperature correct,
normal operation
Flashing: hot water tank cooling function
16 Actual solar circulating pump speed (A=Min., E=Max.)
92
13
15
1
2
3
4
14
5
19 20 21 22
A
B
Cod. 3540V010 - 07/2010 (Rev. 00)
17 18
6
7
16
23
8
C
D
17 Activated: upper hot water tank sensor ok, normal ope-
ration
Deactivated: upper hot water tank sensor fault
18 Activated: hot water tank sensor ok, normal operation
Deactivated: hot water tank sensor fault
Flashing: hot water tank limit temperature function
19 Upper hot water tank temperature sensor info
20 Hot water tank temperature sensor info
21 Solar collector temperature sensor info
22 Solar collector return temperature sensor info
23 Activated: elimination of excess heat/supplementary
heating demand
Deactivated: no supplementary heating demand/elimi-
nation of excess heat
A - Enter / ON/OFF button
B - Parameter selection button
C - Parameter selection button
D - Service menu access / Information button