TYPES AND CHARACTERISTICS
900INT
230 Vac Under grounded gear motor, with grease, with opening and closing limit
900INT-24
24 Vdc Under grounded gear motor, with grease with opening and closing limit
900INT-OIL
230 Vac Under grounded gear motor, lubricated in oil bath, with opening and closing limit.
TECHNICAL DATA
Suggested control unit
Power supply
Maximum power
Idling current
Capacitor
Protection
Maximum torque
Shutter opening
Working cycle
Thermal protection
Opening time (90°)
Working temperature
Motor weight
The series of actuators UNDER, has been devised to serve gates up to 600 Kg with leaf up to 3 meters wide
(look at the table technical data). Before proceeding with the installation, please make sure that your gate
opens and closes freely, and that:
• Hinges and pins are in optimum condition and properly greased.
• No obstacles are within the moving area.
• There is no friction with the ground or between the leaves.
• Your gate shall be equipped with central and side stops, which are fundamental for the good system
operation.
600
500
400
300
200
100
1
900INT
(CT-2/CT-201)*
230 Vac
230 W
1 A
10 µF
67 IP
300 Nm
108° Max
30 %
150° C
20 sec
-20° +70°C
11 Kg
2
Max. leaf lenght (m)
OVERALL DIMENSIONS
11
900INTOIL
900INT-24
(CT-2/CT-201)*
(CT-824S)*
230 Vac
24 Vdc
230 W
120 W
1 A
10 µF
67 IP
67 IP
300 Nm
250 Nm
108° Max
108° Max
80 %
80 %
150° C
20 sec
21 sec
-20° +70°C
-20° +70°C
11 Kg
10,8 Kg
2,5
5 A
-
-
3