EN
2 - PRODUCT OVERVIEW
2.1 - Description of the product
The RAY gear motors are destined to be installed in systems for the
automation of gates with hinged doors.
The RAY gear motors have been designed and constructed to be
fitted onto hinged doors within the weight limits indicated in the
2.2 - Model and technical characteristics
Code
RAY2524
RAY2524E
3 - PRELIMINARY CHECKS
Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the maxi-
mum permissible operating limits specified in Fig. 2
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
starting point may be higher than under normal conditions.
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if left
in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
10
Description
Gear motor for hinged doors with max length 2.5 m and weight 250 Kg
Gear motor for hinged doors with max length 2.5 m and weight 250 Kg with encoder
TECHNICAL DATA
MODEL
TECHNICAL SPECIFICATIONS
Power supply
Engine power
Absorption
Thrust force
Speed
Degree of protection
Operating temperature
Weight
Working stroke
technical specifications table.
The use of gear motors for applications which differ from those
indicated above is prohibited.
RAY2524
RAY2524E
24 Vdc
120 W
5 A
1500 N
0.016 m/s
0.016 m/s
IP44
-20°/+55°C
-20°/+55°C
6 Kg
415 mm
- Provide the power system with a disconnecting device with a gap
of contacts enabling full disconnection under the conditions dictated
by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
24 Vdc
120 W
5 A
1500 N
IP44
6 Kg
415 mm