Reagent tank suction connection
Cut pipe to length and fix one end using the conical nut on the left-hand port of the injection pump. Place
the other end of the pipe in the reagent tank. Fix the ceramic counterweight. The end of the pipe with its
counterweight should hang about 5 cm above the bottom of the tank.
Injector connection
Cut the pipe to length and fix one end to the right-hand port of the injector pump using the conical nut.
Fix the other end on the injector rod.
It is preferable to use liquid pH+ or pH- reagents as the case may be. We strongly advise against using
pH correctors in powder form or hydrochloric acid.
ELECTRICAL WIRING DIAGRAM (shown as example)
CIRCUIT BREAKER
HYDRAULIC INSTALLATION (example on collar unit)
PLUG HOLE
SKIMMERS
Switch to "On" position and wait 2 or 3 minutes until the reading settles and indicates the pH value of the
water. Check this value manually. If required, change it (see calibration).
Check that the A or B light corresponds to reagent tank contents: pH- = A; pH+ = B.
CLOCK
CONTACTOR
PUMP
AUTOMATIC MODE
FILTER
PUMP

INITIAL START-UP