8 FIRST START-UP

The first time you apply voltage to your unit, you will see parameter 1.1 that belongs to menu 1 General
Setup, which at the same time is the start-up wizard.
You will also see this screen after restoring the factory settings.
In this menu, enter the basic parameters of the installation prior to programming the time intervals that you
wish to have the pump filtering.
1 . 1
Select the desired language and press the F2 key (next) and with the ( ) key, move to parameter 1.2 to
continue with the setup wizard.
1 . 2
In this parameter enter the date and time. The frequency converter will be governed by this for scheduling
the start and stop times. Continue with the button ( ) to change the parameter, go to the parameters, first to
1.3 and then to 1.4, where you will select the units to use for programming.
1 . 3
1 . 4
With the down arrow move to menu 1.5 and indicate the amount water in the swimming pool. This data is
important as the pump will use it along with the time periods to calculate the flow necessary:
1 . 5
The flow of the pump is decided knowing the water contained in the swimming pool and adding the time of
all the time periods programmed.
[e] Winner
26
L A N G U A G E
E n g l i s h
S E T
0 1 / 0 1 / 0 1
V O L U M E
m 3
P R E S S U R E
B a r
P O O L
5 0
T I M E
-
1 0 : 2 0
U N I T S
U N I T S
V O L U M E
m 3
N e x t
N e x t
N e x t
N e x t
N e x t