Inspect Muffler And Spark Arrestor; Valve Clearance; Storage - Generac GP Serie El Manual Del Propietario

Ocultar thumbs Ver también para GP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Service Spark Plug
To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Inspect electrode gap with wire feeler
gauge and reset spark plug gap to 0.028 -
0.031 in (0.70 - 0.80 mm). See
Figure 4-4. Spark Plug
NOTE: Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Inspect Muffler and Spark
Arrestor
NOTE: It is a violation of California Public
Resource Code, Section 4442, to use or oper-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrestor, as defined in Section 4442, main-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrestor
designed for exhaust system installed on this
engine.
NOTE: Use ONLY original equipment replace-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrestor, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
Owner's Manual for Portable Generator
Inspect Spark Arrestor Screen
Figure
4-4.
1. Loosen clamp (A) and remove screw. See
2. Inspect screen (B) and replace if torn, per-
3. Replace spark arrestor cone (C) and
000211

Valve Clearance

Important: Please contact an Independent
Authorized Service Dealer for service assis-
tance. Proper valve clearance is essential for
prolonging the life of the engine.
Check valve clearance after the first fifty-hours
of operation. Adjust as necessary.
• Intake — 0.15 ± 0.02mm (cold), (0.006 ±
• Exhaust — 0.20 ± 0.02mm (cold) (0.008 ±

Storage

General
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
Figure
4-5.
forated or otherwise damaged. If screen is
not damaged, clean with commercial sol-
vent.
screen (B). Secure with clamp (A) and
screw.
Figure 4-5. Spark Arrestor Screen
0.0008 in)
0.0008 in)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Store fuel in a well
ventilated area. Keep fire and spark away. Failure
to do so will result in death or serious injury.
WARNING
Risk of Fire. Verify machine has properly
cooled before installing cover and storing
machine. Hot surfaces could result in fire.
(000108)
C
A
B
000213
(000143)
(000109)
15

Publicidad

Tabla de contenido
loading

Tabla de contenido