2.3. Alarms
The
icon is lit when at least one alarm has occurred on one of the data
managed by the WIND display.
A sensor alarm appears when it is activated (different from 0) and the measurement
has exceeded the upper or lower threshold previously defined. This alarm is then
shown by:
The flashing
The data concerned by the alarm flashing,
Automatic lighting of the LCD backlighting to its highest level,
The internal buzzer sounds,
The buzzer or the external lights (if connected) are activated.
An alarm can be cancelled and inhibited for 3 minutes by pressing on any key on the
keypad. After this period, a new alarm may be triggered when the measurement
sensor once again exceeds the programmed thresholds.
Several devices interconnected on the bus, can be used to relay a sensor alarm to
other compatible displays present on the network. Example: an apparent wind speed
alarm can be viewed on all "WIND" displays present on board.
A high threshold can be set on the "apparent wind speed" and a low threshold on
"battery voltage".
2.3.1. Setting the apparent wind speed alarm threshold.
To set the high wind speed alarm:
menu
Press
, then again on
page "SPd" is displayed, and adjust the value using the
and
keys.
2.3.2. Setting the battery voltage alarm threshold.
To set the battery voltage alarm threshold:
menu
Press
, then again on
alarm page "bAt" is displayed, and adjust the value using
the
and
keys.
Press 2 seconds
timeout after 10 seconds.
icon
menu
until the wind speed alarm
menu
until the battery voltage
to exit setup mode, or automatic
Installation and Operation Manual S400 series
10