Thru-the-Wall Installation continued
Figure 71
/
" MINIMUM
3
4
SLEEVE FRONT
1" THICK LUMBER
1" MINIMUM
INSIDE WALL
EXTERIOR WALL
STEP 7. Cut two pieces of standard 1" lumber (supplied by installer)
to the length and width required. Place in front and back of
bottom sill channel as shown in Figure 71. Secure with nails
(supplied by installer).
STEP 8. Seal all holes in the sleeve with caulking compound (supplied
by installer).
Figure 72
SOLID MASONRY CONSTRUCTION
NOTE: ELECTRICAL RECEPTACLE LOCATION
FROM POINT "X" MUST BE WITHIN A MAXIMUM
RADIUS OF 69" FOR 115V UNITS.
FRONT EDGE OF LOUVERS
MUST ALWAYS BE OUTSIDE OF
EXTERIOR WALL SURFACE
MAX. WALL THICKNESS
ALLOWED 8
1
CABINET
MORTAR
/
" SLOPE DOWN.
1
4
POSITION AND SECURE
SLEEVE DOWNWARD.
SLOPE OUTSIDE FOR
DRAINAGE.
1
/
" SCREWS (F IN PARTS LIST) / 3 EA. SIDE
1
2
/
"
NAILS MAY BE USED IF DESIRED.
2
STEP 9. Complete the installation by following Steps 5.3 through 7 of
Standard Window Installation (Pages 30, 31). Window seal
gasket mentioned in Step 6 will not be required.
IMPORTANT: Before operating your unit, read CIRCUIT PROTECTION
of Standard Window Instructions under Step 7 (Page 31).
CAULK ALL SIDES
POINT "X"
/
" MINIMUM FRONT
3
4
EDGE OF SLEEVE TO
INSIDE WALL SURFACE.
TRIM AROUND THE
SLEEVE WITH A
SUITABLE WOOD
MOULDING AND
FINISH TO SUIT.
CAULK ALL AROUND
SLEEVE ON OUTSIDE
TO INSURE A WEATHER
TIGHT SEAL.
ELECTRICAL
RECEPTACLE
FRR092
FRR093