Keypad / Installation
Toggles the pressure setpoint
between 40, 60, and 70 PSI
Runs the Drive at 45 Hz
(with no pressure control)
Hazardous
to allow the installer
pressure.
to pump out the well
Do not connect to
system or restrict
discharge flow
when running in
Changes the display to
"Pump Out"
the previous screen
mode.
Selects menu items and
confirms numeric value changes
Power is on to the Drive
The Drive is in Temporary Performance
Mode (TPM) or Jam condition
A fault has occurred
Displays the Drive's
current operating conditions and
changes the display parameters
Figure 2: Keypad functions
INSTALLATION
Mounting (See Figure 3)
Mount the drive in an easily accessible area with tempera-
ture maintained between –4°F and 104°F (–20°C to 40°C).
NEMA 1 enclosures must be mounted indoors; NEMA 3R
enclosures may be mounted outdoors with the same ambi-
ent temperature limits.
To mount the drive, mark the location of the top keyhole
on the wall or stud. Drive a screw into the structure and
hang the drive on it. Back out the screw on the bottom of
the front cover and lift the cover off. Mark the locations of
the bottom two mounting holes. Mount the drive with
screws in all three holes.
Be sure that the ventilation holes are not blocked and that
there is enough space around the drive to allow free air
flow (minimum 3" clearance, top, bottom, and sides).
Once the drive is mounted, you are ready to connect
the wires.
Keypad Nomenclature and functions
(default is 60)
Stops the motor
Checks for line fill, then
starts the pump in constant
pressure mode
Figure 3
Views and changes parameters
Shows the last 15 faults
With code, locks and unlocks the
password protected keys (default
password is 7777)
Toggles between English, Spanish,
and French (Default is English )
The left and right arrows
move the cursor.
The up and down arrows scroll through
the menus and change numeric values.
Resets the fault
that stopped the pump