Ecler Mimo88 Manual De Instrucciones página 20

Ocultar thumbs Ver también para Mimo88:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Output Limiter (x8)
Built in Signal Generator
Stereo Linking
Mix Matrix
Pager (x4)
Mechanical
Dimensions
Weight
Supply
Mains
Power consumption
Miscellaneous
Management Connectivity
Expansion LINK BUS (16x16 ch.)
Remote Bus
GPI
GPO
Aux. Power Supply for Remotes & GPI
Time and date retention (battery)
RTC accuracy
SOFTWARE
EclerNet Manager
36
Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Ratio: inf:1 (limiter)
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Sine: from 20 Hz to 20 kHz
Polarity: from 20 Hz to 20 kHz
White noise
Pink noise
Adjacent input / output channels
Linked processing
Matrix routing linked
Size: 8x8 (1-MIMO88)
Size: 16x16 (2-MIMO88 with expan. link bus)
Vol: Input, Output, Crosspoint
Mute: Set/Clear individual, row, column, all
Input /output Mono/stereo selector
Meter: Input /output VU and clip
Input: IN1 to IN8 (or to IN16 in 16x16)
Priorities: 4
Depth: 0 dB to 80 dB
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Chime Source: None, Melody 1, Melody 2
Chime Volume: from –12 dB to 0 dB
482.6x44x266.5mm
3.5kg
90-264VCA 47-63Hz
75VA
Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to 100m.
Proprietary over CAT5, Xover cable up to 100m.
2, over twisted pairs; up to 1km (see specific specs.)
8, from 0 to 10VDC or TTL level
8, 3 poles isolated relay; 1A, 48VDC max.
+12VDC, 1.2A. max. (short circuit protected)
1 month aprox. (ambient temperature dependant)
±1 minute /year
(1 max, 4 min)