- Connect the cable to the SlaveBoard first. Then
cut the cable to the necessary length.
- Start to connect the filter module that is closest to
the Panel.
Fig. 4.14
Remove the lid (A).
Remove the left dust cap (E).
Loosen the cable gland (C) from the cable and remove the
nut.
Put the cable into the SlaveBoard and put the nut (B) back
over the cable.
Connect the cable to the CAN IN connector (D) on the PC
board.
Tighten the cable gland.
Filter pressure
-
(internal sensor)
+
B
Fan pressure
-
(internal sensor)
C
A
+
Fig. 4.14 Connection of SlaveBoard
Fig. 4.15
RS-232
Cut the cable to the necessary length for connection to the
(for service only)
Panel.
CAN Slave
Dustbin
Valves
Indicator LED's
sensor
CAN HMI
Analog
Power
Light tower
output
Wiring colours
CAN Slave
+24V
CAN_H
1 2 3 4 5
CAN_L
GND
SHD
Fig. 4.15 Connection of SlaveBoard  Panel
CAN HMI
1 2 3 4 5
0000112606/200917/0 ControlPro
cable #2
D
E
Fan Pressure
Digital input 1-5
RS485 VFD
sensor
Filter Pressure
Digital input 6-12
sensor
cable #2
red
white
blue
black
drain wire (with
shrink tube)
In case of multiple filter modules
Proceed with paragraph 4.4.5
In case of one (1) filter module
Fig. 4.16
Put the termination plug (A) on the CAN OUT connector on
the PC board.
Fig. 4.17 + Fig. 4.18
Make sure that the DIP switches are correctly set.
Close the lid.
4.4.5
SlaveBoard  SlaveBoard
In case of multiple filter modules, you must make a serial
connection of the cables.
Cable #3 is supplied with two cable glands and a connector at
both ends. The number of cables is equal to the number of
filter modules.
(CAN IN)
Fig. 4.16
Remove the lids of all SlaveBoards.
Remove all dust caps.
Loosen the cable glands from the cables and remove the
nuts.
Put the cables into the SlaveBoards and put the nuts back
over the cables.
Connect a cable to the CAN OUT connector of the first filter
module.
Connect the other end of the cable to the CAN IN connector
of the next filter module.
Continue the same way to connect all SlaveBoards.
Put the termination plug
the last filter module.
Tighten all cable glands.
FIRST filter module
CAN Slave
CAN HMI
Fig. 4.16 SlaveBoard  SlaveBoard
address SlaveBoards
To arrange the compressed air valves of the entire filter
system to pulse in the most effective sequence, you must
configure the DIP switches of each individual filter module.
The DIP switch module
[page 8]
are pre-configured in the factory.
21. Address configuration pos. 1-4: according to number 1
22. Supplied with Panel  SlaveBoard cable (#2)
23. The red module on the PC board
21
- Due to the cable length, you can only make
horizontal and vertical connections. It is not
possible to make diagonal connections.
- Refer to Fig. IV on page 82 for an example of
the correct connection sequence.
- For the position of the CAN IN and CAN OUT
connectors, refer to Fig. III on page 82.
(A) on the CAN OUT connector of
22
LAST filter module
FIRST
LAST
contains 6 DIP switches. Position 5+6
23
cable #3
A
EN - 10