NOTE: The rating plate stipulates the maximum possible output of DC voltage (G) and current
(H). The setting of your particular unit may be different. For the settings on your unit see the
front panel label (7).

OTHER TECHNICAL DATA

Storage Temperature Range:
Relative Humidity Range:
Operating Temperature Range:
REPAIRS
Repairs must only be carried out by qualified personel.
Use only original equipment manufacturers (OEM) parts for repairs.

ELECTRICAL FEATURES

1. System input 115V 60Hz (other input voltages available on request).
2. Charging parameters insensitive to 10% system voltage variations.
3. ISO isolation transformer, class H
4. Efficiency > 80%.
5. Output ripple at max load below 150mV.
6. Accuracy of power and voltage measurements 1%.

ELECTROMAGNETIC COMPATIBILITY

The tests of electromagnetic compatibility (EMC) on these devices were carried out in compliance
with the CEI EN55014-1+A2(04/98-06/99) and CEI EN 55014-2(10/98) STANDARD norms, with
the test instructions and conditions as requested by the norms.
As to the immunity the devices are classified as Category II.
ELECTRICAL APPROVALS
The CBSW1-S and CBSW2-S range of battery chargers are CSA certified to CAN/CSA-C22.2 No
107.2 and are also approved to UL 1236.
E-Mail
info@bti-chargers.com
- 40 to +45 degrees Celcius
0 – 80%
-10 to 45 degrees Celcius
NORM
EN 55014-1+A2
EN 55014-1
EN 61000– 3-2
EN 61000– 3-3
EN 61000– 4-2
EN 61000– 4-4
EN 61000– 4-5
EN 61000– 4-6
EN 61000– 4-11
Ph: 905.636.9865 Fax: 905.636.9879
RESULT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT
COMPLIANT