Consulting Programmed Actions; Tips And Tricks - Daikin EDLQ036BA6VJU1 Operation Manual

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
You automatically return to step 4. By pressing the pr button
several times, you return to previous steps in this procedure and
finally return to normal operation.

Consulting programmed actions

Consulting space cooling or space heating actions
Consulting space cooling or space heating is done in the
same way. At the start of the consulting procedure space
cooling or space heating is selected. After that, you have to
return to the start of the consulting procedure to consult
the other operation mode.
Consulting space cooling or space heating is carried out as follows.
NOTE
Returning to previous steps in this procedure is done
by pressing the pr button.
1
Use the = button to select the operation mode (cooling or
heating) you want to consult.
Press the < button.
2
The actual mode is blinking.
3
Press the < button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to consult by means of the pi
and pj buttons.
The selected day is blinking.
Press the < button to confirm the selected day.
5
The first programmed action of the selected day appears.
Use the pi and pj buttons to consult the other
6
programmed actions of that day.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
Consulting domestic water heating, booster heater or quiet
mode
Consulting domestic water heating, booster heater or quiet mode is
carried out as follows.
NOTE
Returning to previous steps in this procedure is done
by pressing the pr button.
Press the < button.
1
The actual mode is blinking.
Use the pi and pj buttons to select the mode you want
2
to consult (quiet mode
s
water heating
w
).
The selected mode is blinking.
3
Press the < button to confirm the selected mode.
The first programmed action is displayed.
Use the pi and pj buttons to consult the programmed
4
actions.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
EDLQ036~054BA6VJU1 + EBLQ036~054BA6VJU1
Unit for air to water heat pump system
4PW56183-1
, booster heating
m
or domestic

Tips and tricks

Programming the next day(s)
After confirming the programmed actions of a specific day (i.e. after
pressing the < button for 5 seconds), press the pr button once. You
can now select another day by using the pi and pj buttons
and restart consulting and programming.
Copying programmed actions to next day
In heating/cooling program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "1" to "2").
To copy programmed actions to the next day, proceed as follows:
Press the < button.
1
The actual mode is blinking.
2
Use the pi and pj buttons to select the mode you want
to program.
The selected mode is blinking.
You can leave programming by pressing the pr button.
3
Press the < button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to copy to the next day by means
of the pi and pj buttons.
The selected day is blinking.
You can return to step 2 by pressing the pr button.
Press the < and pr buttons simultaneously for 5 seconds.
5
After 5 seconds the display will show the next day (e.g. "2" if
"1" was selected first). This indicates that the day has been
copied.
You can return to step 2 by pressing the pr button.
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the < button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the < button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
Press the < button.
1
The actual mode is blinking.
Use the pi and pj buttons to select the mode you want
2
to delete (quiet mode
s
, booster heating
heating
w
).
The selected mode is blinking.
Press the < and ba button simultaneously for 5 seconds to
3
delete the selected mode.
Deleting a day of the week (cooling or heating mode)
1
Use the = button to select the operation mode (cooling or
heating) you want to delete.
Press the < button.
2
The actual mode is blinking.
Press the < button to confirm the selected mode.
3
The actual day is blinking.
4
Select the day you would like to delete by means of the pi
and pj buttons.
The selected day is blinking.
Press the < and ba button simultaneously for 5 seconds to
5
delete the selected day.
m
or domestic water
Operation manual
10

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido