_MS660.book Seite 86 Montag, 2. August 2010 8:03 20
Programming MagicSafe
Function 24 (Visual signals)
A connection to the indicator cables has been provided at the factory. In the
event of an alarm, both alarm system indicator outputs generate a +12 volt
interval signal.
If you wish to connect the optical signals via the hazard lights switch, you
must program this to "Hazard lights". In this case, a short earth signal is
switched from both alarm system indicator outputs. After the alarm has
finished (30 sec.), a further earth signal is switched to deactivate the hazard
light system.
9.3
Programming
Starting the programming mode
➤ Deactivate the alarm system using the remote control: Press the "Unlock"
button.
➤ Open the driver's door and switch on the ignition.
➤ Press and hold the "Unlock" button and switch the ignition off.
➤ Release the "Unlock" button.
✓ The status LED lights up. You have now accessed the program menu.
NOTE
I
If 30 sec. elapse without a button being pressed, the program menu
will be quit automatically.
Programming functions
The functions are programmed by pressing the button "Lock" or "Unlock" re-
peatedly in accordance with the number of the function, see list, page 81.
Example: You wish to activate the convenience locking function. This is
function 4. Press the "Unlock" button 4 times to activate.
The status LED goes out briefly each time the button is pressed to confirm
the selection. To confirm the programming step, the status LED goes out for
2 sec.
The preferred value is saved.
➤ Perform all the required programming steps.
➤ To end programming, switch the ignition on.
86
MagicSafe MS660