Electrical Wiring - Vimar SL230.T Manual De Instrucciones Para La Conexión Y El Uso

Tarjeta de mando dip 230/120 vca para cancelas correderas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
SL230.T - SL230.T.120

6. Electrical wiring.

Description of terminals:
Terminal block M1
Terminal number
Board marking
1
2
3
4
5
6
7
8
9
10
11
12
13
Terminal block M2
14
15
16
17
18
19
20
21
The sum of the absorptions of the 24VDC accessories must not exceed 300 mA
Wiring for power supply line, flashing lamp and electric motor:
Description
P.IN
Input (N.C.) for opening and closing safety devices
SEQ
Push button (N.O.) for opening and closing (sequential or start)
STOP
Push button (N.C.) for stop
PED
Push button (N.O.) for pedestrian opening
SCL
Input (N.C.) for closing safety devices (reopening)
SOP
Programmable input for non resistive (N.C.) or resistive 8K2 sensitive edge
LSC
Input (N.C.) for left limit switch (activated with right-hand cam)
LSO
Input (N.C.) for right limit switch (activated with left-hand cam)
COM
Common inputs and indicator light (negative)
+AS
Positive for 24 VDC accessories power supply
-AS
Negative for 24 VDC accessories power supply
+P.OUT
24VDC positive programmable output for safety test or 2
+WL
Positive for indicator light 24V, 2W max
MOP
Motor opening direction output
MCL
Motor closing direction output
MCOM
Common motor winding output
FL
Flashing lamp 230/120 V
FL
Flashing lamp 230/120 V
N
Input for 230/120 V 50 Hz line (NEUTRAL)
L
Input for 230/120 V
Input for earth connection
COMMON
(momentary stop)
50 Hz 25 W max (NEUTRAL)
50 Hz 25 W max (PHASE)
50 Hz line (PHASE)
230 VAC
230/120 VAC
EN
radio channel
nd
EARTH
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sl230.t.120

Tabla de contenido