Deleting a single button saved on the remote control
1. Press push button P2 and hold it down. LED DL.S starts to flash (1
2. Do not release push button P2. The flashing becomes faster (2
3. Do not release push button P2 until it flashes faster (3
4. Release push button P2.
5. Within 10 seconds, activate the button of the remote control to be deleted.
6. Deletion procedure completion will be signalled by the flashing of the flashing lamp, followed by the LED DL.S that stops flashing.
Deleting all the saved remote controls.
1. Disconnect the power supply to the control unit.
2. Reconnect the power supply to the control unit by holding down push button P2.
3. Wait for the DL.S LED to stop flashing.
4. At the end of this procedure, all the remote controls in memory are deleted.

11. Programming.

Before you begin programming, we recommend you save at least one remote control associated with input SEQ.
Manual tuning procedure to position the gate.
In order to perform the gate positioning manoeuvres before you begin any learning or checks, there is a function designed to move the motor, both
opening and closing, in dead-man mode.
To enter this mode, press both push buttons P1 and P2 simultaneously, then LED DL.S lights up permanently to indicate dead-man tuning mode.
Release the buttons.
Push button P1 now controls opening while push button P2 controls closing, or vice-versa depending on the position of DSW1 Dip switch7.
Simply hold down one of the two push buttons to move the gate.
Exit dead-man mode by pressing both push buttons P1 and P2 simultaneously.
Selecting the direction of opening.
The control unit is equipped with dip switches to select the direction of gate opening.
If the gate opens towards the right, set DSW1 Dip switch 7 to OFF and switch off the power supply to the control unit and then back on again.
If the gate opens towards the left, set DSW1 Dip switch 7 to ON and switch off the power supply to the control unit and then back on again.
.
flashing frequency).
st
flashing sequence).
nd
flashing frequency).