Before carrying out any cle-
aning or maintaining opera-
tions, the appliance needs to
be removed from the electric
grid. If the appliance is not
provided with a non-separa-
ble flexible cable and plug,
or with another device ensu-
ring disconnections from the
grid, with an opening distan-
ce between the contacts of
at least 3 mm, then such di-
sconnecting devices must be
supplied within the fixed in-
stallation.
If the fixed appliance is
wed
with a supply cord and a
plug, the appliance has to be
put in a place where the plug
can be reached easily.
Before carrying out the instal-
lation of the appliance, please
check that all components are
not damaged. In such a case,
make contact with your retai-
ler and do not proceed with
the installation.
Should the product show any
anomaly, disconnect the ap-
pliance from the power supply.
When the range hood and ap-
pliances supplied with energy
other than electricity are si-
multaneously in operation, the
negative pressure in the room
must not exceed 4 Pa (4 x 10-5
bar).
SLT968 EM and SLT 968 EM models can be
used only if connected with external motors ma-
nufactured by the same producer.
SLT968 and SLT969 models are equipped with
internal motor.
PANEL OPENING
It is possible to open the panel, which cover the
grease filters, slightly pulling the panel on a side,
as shown on fig. 1.
In order to make the hood working properly, it is
recommended to install the appliance at a distan-
ce of 2000 - 2100 mm from the floor.
endo-
Before starting the appliance installation, please
check that all components are not damaged, in
such a case contact your retailer and do not carry
out installation.
Furthermore, please read carefully all of the fol-
lowing installation instructions.
- Use an exhausting pipe whose maximum length
does not exceed 5 meters.
- Limit the no. of elbows in the piping, since each
elbow reduces the air capacity of 1 linear meter.
(Ex.: if you use no. 2 x 90 ° elbows, the length of
piping must not exceed 3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for the
whole length, or same section.
- Use piping approved by standards in force.