Installing Preparation; Ducting Options And Examples; Venting Methods - ELICA VOLTERRA Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ducting Options and Examples

Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.

Venting methods

The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless
(Recirculating) version. Attach a charcoal filter and the deflector F on the duct cover support bracket G. Fumes and vapours
are recycled through the top grille H by means of a duct connected to the transition B and the transition mounted on the deflec-
tor F.
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 6" Round Pipe.
Pipe
Transition (B)
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types of walls/ceilings.
However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
CAUTION:
FOR 9' CEILINGS: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30" (76, CM) MINIMUM ABOVE THE
COOKING SURFACE.
Check your ceiling height and the hood height maximum before you select your hood.
Use only Metal duct system. DO NOT use flexible plastic ducting.
NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust
required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems.
To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer's guide-
lines and safety standards such as those published by NFPA and ASHRAE.
This Hood Must Use an 6" Round Duct.
Roof pitch w/
Flashing and cap
Pipe
Transition (B)
Vertical Discharge
6
Pipe
Transition (B)
Sidewall cap
Charcoal
with gravity
filter
damper
Recirculating
Deflector (F)
Top grille (H)
Support bracket (G)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Evl436ss

Tabla de contenido