Specifications - Temper KOBAN KEV-01 Instrucciones De Operación

Adaptador de prueba para estaciones de carga de vehículos eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Test Adapter for Electric Vehicle Charging Stations

10.Specifications

Functions
PE Pre-Test
PP Simulation
CP States
CP Error "E"
PE Error (Earth Fault)
Outputs (for test purpose only)
Measuring Terminals L1,L2,L3,N and PE
Mains Socket
Mains Socket Protection
CP Signal Output Terminals
General Features
Input Voltage
Type 2 Test Cable
Weight
Dimensions (LxWxH)
Safety
Measurement Category
IP-Rating
Pollution Degree
Protection Class
Working Temperature Range
Storage Temperature Range
Reference Humidity Range
Working Humidity Range
Altitude Above Sea Level
18
Yes
NC/13A/20A/32A/63A
A (Electric vehicle not connected)
B (Electric vehicle connected, not ready to charge)
C (Electric vehicle connected, ventilation not required, ready to charge)
D (Electric vehicle connected, ventilation required, ready to charge)
On/Off
On/Off
Max. 250/430V,CAT II 300V,max.10A.
Max.250V,CAT II 300V, allowed current max.10A.
Note: Do not load mains socket simultaneously with measuring terminals!
Fuse 10A/250V,5x20mm, Magnetic tube produced by Xunlibang.
Approx, ±12V, CAT 0 (Under normal condition).
In case of wrong wiring or error of the charging station these terminals
may become hazard =>up to max. CAT II 300V against PE.
Up to 250V (Single phase system)/up to 430V (Three phase system),
50/60Hz, max 10A.
AC charging mode 3, suitable to IEC62196-2 type 2 socket outlet or fixed
cable with vehicle connector (Type 2, 7P three-phase).
Approx.1kg
Adapter size: 227x109x63mm (Length without connection test cable)
Handle size: 250x115x61mm (Length without connection cable)
IEC/EN 62851-1/IEC/HD 60364-7-722
300V CATII
IP54
2
II
0 to 40°C
-10 to 50°C
10 to 60% relative humidity w/o condensation
10 ro 85% relative humidity w/o condensation
Max. 2000m

Publicidad

Tabla de contenido
loading

Tabla de contenido