Cleaning & Maintenance - Renfert 2954-0000 Instrucciones Para El Servicio

Ocultar thumbs Ver también para 2954-0000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
4. Installation /
Commissioning
4.1 Setting up and Connecting
the Unit
1. Inspect the tank for proper installation (Fig. 1).
2. Check the voltage information on the nameplate.
3. The unit is operational with two tanks. To connect
additional tanks, please refer to Installation
Instructions, No. 21-9498.
4. Remove the foot switch from its shipping location
in the blasting chamber.
5. Connect the foot switch to the sandblasting unit
(red + yellow). Make sure to both pneumatic
hoses are fully inserted up to their stops (Fig. 2).
6. Connect the compressed air supply to the sand-
blasting unit. To do this, loosen the screw-on air
coupling on the unit (Fig. 3).
7. Push the screw-on coupling over the supplied blue
compressed air hose (Fig. 4).
8. Connect the compressed air hose to the unit and
tighten the coupling sleeve (Fig. 5a).
9. Connect the compressed air hose to the com-
pressed air supply (Fig. 5b).
10. Do not bend or kink the hoses (Fig. 6)!
11. Connect the dust extraction hose to the extraction
tube (Fig. 7).
Do not connect the unit to the
mains power supply yet!
4.2 Fluorescent Lamp
Installation
1. Remove the plastic sheet from both sides of the
lamp cover (Fig. 8).
2. Push the lamp cover over the fl uorescent tube
(Fig. 9).
3. Insert the tube horizontally (Fig. 10).
>>> Please observe the safety instructions
(Sec. 3)!
4.3 Starting the Unit
1. Connect the mains power cord to the sandblasting
unit (Fig. 11), then plug the power cord into the
wall outlet (Fig. 12).
2. Switch the unit on (Fig. 13).
4.4 Adjusting the Operating
Pressure
1. Select the sandblasting tank (Fig. 14).
2. Adjust a blasting pressure of 1-6 bar [14.5–87 psi]
(Fig. 15). The pressure is displayed on the mano-
meter (Fig. 15a). The pressure adjustment applies
to all sandblasting tanks.
4.5 Filling the Sandblasting
Tanks
Caution: Never press the foot switch during
fi lling. Before closing the tank, be sure to clean
the threads in the cover and the tank to remove
any abrasive residue.
Note: Even though the manometer may indicate
pressure, the sandblasting tanks are only under
pressure if the foot switch is engaged.
1. Unscrew the tank cover (Fig. 16).
2. Add abrasive up to the maximum fi ll level (the
point where the tank jacket thickens just below the
thread) (Fig. 17). Make sure the abrasive being
used is compatible with the sandblasting tank.
3. Reinstall the tank cover (Fig. 18).
Caution: Do not cross-thread the cover.
Always use only clean, dry abrasive of the appropria-
te grain size (refer to the accessories).
The sandblasting unit is now operational.
5. Cleaning / Maintenance
5.1 Cleaning the Interior
• Use only solvent-free cleansers (e.g., soapy water).
• Remove the grate and vacuum the blasting
chamber (Fig. 19+20).
• Wipe out the tanks and lids only with a dry cloth!
5.2 Condensation
1. Inspect the water separator.
2. Drain any water off through the valve (Fig. 21).
5.3 Blasting Nozzle
Replacement
1. Refer to insert no. 21-9162 for installation.
2. Inspect for abrasive residue.
3. Inspect the seal ring position.
5.4 View Port Replacement
Please refer to the installation instructions provided
with the new pane (insert no. 21-9811).
5.5 Sandblasting Hose
Replacement
1. Disconnect the sandblasting unit from the com-
pressed air supply (Fig. 5,4,3).
2. Refer to insert no. 21-9162 for the installation
instructions.
5.6 Fluorescent Tube
Replacement
1. Pull the fl uorescent tube horizontally out of its
socket (Fig. 10).
2. Remove the cover (Fig. 9)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2954-1000

Tabla de contenido