Global ERASE operation
With command and selection inputs
1/ Select «Erase» mode by setting the Erase input to
«0».
2/ Make sure that the «Global» input is set to «0» and
that the «Add/Remove» input is disabled.
3/ Press any key on any valid remote control.
4/ Exit «Erase» mode by setting the Erase input to
«1».
Result of the operation:
•
No output can now be activated by any remote-control. The LED flashes twice.
In the case of all the procedures described, the mode chosen can be exited after several training operations. It
is not compulsory to exit the current mode then return if several operations need to be carried out. Each action is
carried out when the key is pressed on the remote control.
6.4.
Technical specification
The number of remote controls that can be stored in the receiver and the maximum number available from the
digital outputs depends on each ARF18 receiver. This information is available in the user guide for each receiver.
6.5.
Summary of registers
Access
W
W
W
W
W
Gamme ARF18 UG V1.6
Registers
Function
S801
Starts the training
process for digital
output 1
S802
Starts the training
process for digital
output 2
S803
Starts the training
process for digital
output 3
S804
Starts the training
process for digital
output 4
S805
Starts the training
process in global
mode
With AT commands
1/ Enter the following AT command:
ATS805=1 in order to select Erase in global mode.
2/ Press a key on any remote control.
3/ Exit «Erase» mode by setting the register used to
«0». ATS805=0.
Description
'0': Exits the training procedure (default value)
'1': Switches to Erase mode for digital output 1
'2': Switches to Add/Remove mode for digital output 1
'0': Exits the training procedure (default value)
'1': Switches to Erase mode for digital output 2
'2': Switches to Add/Remove mode for digital output 2
'0': Exits the training procedure (default value)
'1': Switches to Erase mode for digital output 3
'2': Switches to Add/Remove mode for digital output 3
'0' : Exits the training procedure (default value)
'1' : Switches to Erase mode for digital output 4
'2' : Switches to Add/Remove mode for digital output 4
''0' : Exits the training procedure (default value)
'1' : Switches to Erase mode in global mode.
'2' : Switches to Add/Remove mode in global mode.