WALT tool is double insulated in
#
E
accordance with EN 50144;
therefore no earth wire is required.
115 V units have to be operated via a
@
failsafe isolating transformer with an
earth screen between the primary and
secondary winding.
Mains plug replacement
(U.K. & Ireland only)
● Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualifi ed electrician.
E
● Disconnect the plug from the supply.
● Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
● Only fi t 13 Amperes BS1363A approved plugs
fi tted with the correctly rated fuse (1).
● The cable wire colours, or a letter, will be
marked at the connection points of most good
quality plugs. Attach the wires to their
respective points in the plug (see below). Brown
is for Live (L) (2) and Blue is for Neutral (N) (4).
● Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable fi rmly and that the two
leads are correctly fi xed at the terminal screws.
!
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding
1500 W, we recommend to fi t a plug to BS4343
standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
machine (see technical data). The minimum
conductor size is 1.5 mm
rubber jacket and a grounding conductor.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
Conductor size (mm
0.75
1.00
1.50
2.50
4.00
Voltage
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
Fitting a mains plug to 115 V units
(U.K. & Ireland only)
● The plug should be fi tted by a competent
person. If you are in doubt, contact an
authorized D
electrician.
The wires are coloured according to the following
code:
live = brown
neutral = blue
.
● Do not connect the blue or brown wire to the
earth terminal in the plug. Connect as follows:
brown to terminal marked 'L'
blue to terminal marked 'N'
The plug fi tted should comply with BS EN 60309
(BS4343), 32 Amps.
E N G L I S H
. The cable has to have a
2
)
Cable rating (Amperes)
2
6
10
15
20
25
Cable length (m)
7.5
15
25
30
Amperes Cable rating (Amperes)
6
6
6
6
6
6
6
6
10
15
10
10
15
20
15
15
20
25
20
20
25
6
6
6
6
6
6
6
6
6
10
10
10
10
15
15
15
15
20
20
20
20
WALT repair agent or a qualifi ed
E
45
60
6
6
10
6
15
15
20
20
20
25
25
-
-
-
-
6
6
6
6
6
6
6
10
15
15
15
20
20
25
-
25