Block Diagram Of The Device; Installation; Preparation - Aprimatic A40M-2 Professional Instrucciones Para La Instalación

Microprocesador diseñado para operar 2 motores con un máximo potencia absorbida de 250 w.
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Device with an Aprimatic microprocessor designed to operate 2 motors with a maximum
absorbed power of 250 W.

1.1 BLOCK DIAGRAM OF THE DEVICE

L1
Start LED
Always OFF - it comes ON following the start command
L2
Stop LED
Always ON - it goes OFF following the stop command
L3
Photocell/safety LED
Always ON - it goes OFF following the safety signal
L4
Motor 1 relay LED
L5
Direction relay
L6
Motor 2 relay LED
L7
Electric lock relay LED
L9
Pilot light and test LED
J1
Signal terminal board (inputs)
J2
Power supply terminal board (outputs)
J3
Decoding board/plug-in radio receiver connector
J4-J5
Optional board connector
T1
Transformer
F1
Motor power supply 5A fuse
F2
Electric lock 2A fuse
F3
24VDC power supply 2A fuse
K1
Motor 1 relay
K2
Motor 2 relay
K3
Direction relay
K4
Electric lock relay
SW1
Time setting dip-switch
SW2
Functioning mode dip-switch
U1
Microprocessor
C14-C15 Capacitors 15µF 250V
CAUTION - The product must only be installed by qualified servicing and/or installation
personnel.
CAUTION - The electrical system must comply with the current regulations in the
country where the product is installed.

2.1 PREPARATION

Before installing the device, prepare the tools required for securing it to the wall and to
make the electrical connections. The following are also required:
Closing
Opening
Blue (common lead)
Closing
M1 - To control a single leaf
Opening
Blue (common lead)
APR02001.EPS
M2 - For leaf opening delay (standard)
max 250 W
using the optional RA/AS
Flashing light
board.
Enabled for leaf closing
delay (standard) max 250 W

Publicidad

Tabla de contenido
loading

Tabla de contenido