Assembly; Electrical Connections; Functioning Tests - Aprimatic A40M-2 Professional Instrucciones Para La Instalación

Microprocesador diseñado para operar 2 motores con un máximo potencia absorbida de 250 w.
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. expansion wall plugs dia. 6 mm
2. Skintop type PG16 cable clamps
3. a multipole switch with a minimum contact opening of 3 mm
4. an emergency pushbutton
5. approved cables for external use with minimum cross-section of 0.75 and 1.5 mm²

2.2 ASSEMBLY

It is not necessary to drill any holes to fit the device.
1. Secure the device at a minimum height of 30 cm, using the securing holes in the
plastic container.
2. Insert the connecting cables, through the holes in the bottom of the container and
the cable clamps indicated.
3. Fit a multipole switch upstream of the device.
4. Fit an emergency pushbutton in a position where the automation system can be
seen and so that the power supply to the system can be completely cut-off.
5. Use 1.5 mm² section cables for the motor power supply and 0.75 mm² section
cables for 24 VDC devices.

2.3 ELECTRICAL CONNECTIONS

WARNING - Make sure that the mains power supply is turned OFF before making the
connections.
CAUTION - Do not use intercom or telephone cables.
Make the electrical connections as indicated in the diagram alongside.
After completing the connections as indicated, turn ON the mains power supply and
check that the system is functioning correctly, as explained below.

3.1 FUNCTIONING TESTS

When all the connections have been made, it is necessary to check the automation
system, selecting the "Installation" functioning mode.
This functioning mode makes it possible to select the rotation direction.
To select "Installation" mode program DIP-SWITCH SW2 turning switches S1 to OFF,
S2 to ON, S3 and S4 to OFF. This type of functioning only operates during "opening":
press the opening pushbutton to energise the opening relay, when it is released the
relay is de-energised. Thus the first time it is pressed the gate should open.
If, on the other hand, the gate closes instead of opening when this pushbutton is pressed,
it is necessary to invert the motor connections.
230 V ± 10% - 50 Hz
Connect to a 6A differential switch with a sensitivity of 30 mA
Common
Pilot light - 24 VDC 5 W max
Radioreceiver - max 100 mA
STOP pushbutton - Normally closed
Opening safety devices can also be connected
START pushbutton - Normally open
N.B.
Fit a jumper on the normally closed contacts (2 and 3, 7 and 8), if they are not used.
Electric lock - max power 15 W
Photocell - max 150 mA
Closing safety devices
Normally closed contacts (the various contacts
must be connected in series)
APR02002.EPS