Appendix B - Amx/Crestron - Shure ConferenceONE Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

10
9 Appendix B - AMX/Creston
General command structure:
F0
<command byte
h
There are three types of commands: Set, Get and Report:
-
Set: these commands are used to change the status of the power supply (e.g. set the volume). The
supply answers with a Report.
-
Get: these commands are used to find out the status of the power supply. The supply answers with a
Report. The status of the supply is NOT changed.
-
Report: these commands are sent from the power supply anytime the status of the supply changes
(e.g. you turn up the volume at the power supply). It is also sent from the supply after a Set or Get
command.
Command byte
Set commands
> <data byte
h
Data byte
01
01
h
02
h
03
h
04
01
h
05
h
06
h
07
h
08
h
09
h
0A
h
>
F7
h
h
Set the input level,
01
=mute
to 1E
h
h
h
1E
=highest level
h
Increase input level by one step
--
--
Decrease input level by one step
Set the output level,
01
=mute
to 1E
h
h
h
1E
=highest level
h
--
Increase output level by one step
--
Decrease output level by one step
00
Switch input off
h
01
Switch input on
h
--
Toggle input on/off switch
00
Switch output off
h
01
Switch output on
h
--
Toggle output on/off switch