RS09/RS09.120
8 - Dip switch functions:
and back on again for the change to be updated by the control panel:
Dip switch number
Status of dip switch
DIP 1-1
DIP 1-1
DIP 1-2
DIP 1-2
DIP 1-3
DIP 1-3
DIP 1-4
DIP 1-4
DIP 1-5
DIP 1-5
DIP 1-6
DIP 1-6
DIP 1-7
DIP 1-7
DIP 1-8
DIP 1-8
DIP 2-1
DIP 2-1
DIP 2-2
DIP 2-2
Control input operating logic:
Dip 5
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Logic description:
Condominium plus: when the gate is closed the APCH command controls opening, during the opening phase it is ignored. Once opening has completed
the gate is paused for the rest time. During the pause time an APCH command makes the automatic closing time restart from scratch. During closing the
APCH command controls reopening.
Automatic: when the gate is closed the APCH command controls opening, during the opening phase it stops the gate and with an additional command
the gate closes. In the case of complete opening, the gate is paused for the rest time. During the pause time an APCH command makes the gate restart
with closing. During closing the APCH command controls reopening.
Condominium: with the gate closed an APCH input command controls opening, during gate opening the APCH command is ignored by the control unit,
with the gate fully open it stays open for the automatic closing time. With an APCH command during the pause the gate starts to close, an additional
command during closing controls reopening.
Semi-automatic: with the gate closed an APCH input command controls opening. During opening the APCH command stops the gate. When the gate
is fully open and automatic closing is not active, to close the gate before the automatic closing time you need to apply a command via the APCH input,
another APCH command during closing controls reopening.
Step-by-step: with the gate closed an APCH input command controls opening. During opening the APCH command stops the gate. When the gate is fully
open, automatic closing is not active, to close the gate you need to apply a command via the APCH input, another APCH command during closing stops
the gate and another pulse causes reopening.
Close immediately: engaging the photocells causes the gate to close 5 seconds after they are disengaged, regardless of the set rest time.
The control panel can work with or without an encoder. When switching on, the control unit checks for the presence of the encoder on
connector CN6. For operation without an encoder it is necessary to insert the jumper in connector CN6 as shown in the image fig.15 and
power up the control panel. With this configuration, the SENS trimmer and the obstacle detection function are not active. For operation with an
encoder it is necessary to insert the encoder circuit cable in connector CN6 and power up the control panel. With this configuration, the SENS
trimmer and the obstacle detection function are active.
After setting the dip switches it is necessary to jumper the jr1 reset contacts for a few seconds or switch power off
OFF
ON
OFF
ON
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
OFF
The 2CAN output is associated with the second channel of the remote control
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Photo-test function on (photocell checking with each command) see paragraph 4.8
OFF
ON
The AUX output (terminal number 10) flashes during the gate movement, slowly flashing when
OFF
opening, quickly during closing, on steady when the gate is open and off when the gate is closed
ON
The AUX output (terminal number 10) is switched off only when the gate is fully closed
Dip 6
Dip 7
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
Description
Pick-up on starting ON
Pick-up on starting OFF
Pre-flashing off
The 2CAN output is used to feed the photocell transmitters
The STPA input used for the switch sensitive edge connection
The STPA input used for the resistive sensitive edge connection
See table for control input operating logic
Photo-test function off
For opening the gate to the right
For opening the gate to the left
Condominium plus+ close immediately
Automatic+ close immediately
Condominium + close immediately
EN
Logic
Condominium plus
Automatic
condominium
Semi-automatic
Step-by-step