Ampro TechShow ION 230B Manual De Usuario página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

--0.5m
Ta=45℃
2.2 Maintenance
2.2.1 Operation only allowed to qualified person, damages
due to unprofessional operation or remove of any parts in-
side will not be considered in warranty service. There are no
serviceable parts inside the device or package, service only
leaves to authorized dealers.
ION 230B
ENGLISH VERSION
 
Pls make sure minimal 0.5m distance need to kept between the fixture to any
The device can only run with 100-240v voltage, 50/60Hz power, don't connect
to any other wrong power. Disconnect the device from main power before
The device is designed only for indoor usage, pls keep it away from moisture.
Do not expose the device under the sun or directly to any other lighting source.
Never look directly into the projecting lens when the fixture is power on, the
light may trigger epileptic seizures in photosensitive persons or persons with
epilepsy. Especially at beam effect, extreme caution and observance of these
Don't put or install the device on a surface that subject to vibration
The device is supposed to work in the temperate range -15° C and +45° C, do
not use the device when the temperate exceed this range.
The lens, shield need to be replaced when obviously broken, never use the
device when the shield is not completed closed.
Safety I class device, need to be earth connected.
When the fixture is hanged overhead, the safety rope must be fixed to the
bottom of the device to the appropriate fixing point.
Always carry the device by the handles, do not take the head or arm directly
flammable material.
open the shield or maintenance.
safety instructions is mandatory.
or bumps.
for transportation.
2.2.3 Never allow the optical components contact with oil,
fat or any other liquid.
2.2.4 A regular clearance of the device is needed for long-
term usage, this is very helpful to maintain the lifetime and
brightness need to use a soft and lint-free cloth to clean the
optical system, fan and air flowing tunnel.
p. 7

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido