Manual Equalization
Temperature compensation
Voltage share
Ripple
Max. current
Fuse
Protection
LED display
Remote display
Topology
Control
Operating temperature
Storage temperature
Humidity
EMC
Safety
Ventilation
Casing
Mounting
Dimensions
Weight
AC Connections
Battery Connections
Temperature sensors
Important
•
It is very important to note that the inappropriate use of the battery's charging cycle technology can seriously
degrade or even damage it.
•
This is particularly true for cycles where the charge outputs are vastly superior to those recommended by the
manufacturer.
•
Serious risk of battery overheating and discharge of noxious gasses.
•
Please refer to the manufacturer's recommendations for your choice of cycle
•
Regarding the choice of position 09- "Sulphation recovery programme", it is recommended to begin the cycle in
the presence of a technician who can, if necessary, stop the programme quickly. Serious risk of battery
overheating and discharge of noxious gasses.
12v 30A
299770
Activated by the button on the front of the panel - 2 hrs
+/-15mV/°C
30A (+/-5%)
2 x F20A
Against output overload, output short circuit, excessive internal temperature,
excessive battery temperature (optional), faulty external sensor (optional), faulty
overvoltage output, generally faulty fuse.
Microprocessor based RISCC technology
10%-90% (without condensation)
White aluminum with powder coating treatment with plastic side panels
270mm x 290mm x 120mm ( 10.64" x 11.43" x 4.73") HxWxD
2 x 4.0mm² (0.062in²) terminal blocks & earth
2 x 1mm² (0.0155in²) terminal points
Page 5
12v 40A
299703
+/-2%
<1%
40A (+/-5%)
2xF30A
6 LEDs
"Octopus" control panel
Forward 50Hz & built in PFC
0°C - 50°C
-20°C - 70°C
EN50081-1&EN50082-1
EN60335-1
Forced fan cooling
Wall mounted - 4 screws M4
4kg (8.82lbs)
M6 Bolts
24v 20A
299710
+/-30mV/°C
20A (+/-5%
F30A