Please ensure that the correct and proper installation of all electrical connections.
•
It is essential that +DC1 is connected to the main battery
•
Please connect +DC2 and +DC3 to the motor battery and the auxiliary battery respectively
Recommended gauge
Max length
When replacing fuses they should be replaced with fuses that have identical characteristics and
performance levels. REYA cannot be held responsible for any damage caused where fuse types
other than those recommended are used.
Input gauge
Battery access
Recommended gauge
Max length
In order to prevent all risks arising due to the incorrect use of this device, please carefully read the list of possible
situations or faults that are not covered by the warranty.
• This device is not protected against reverse battery polarity. Irreversible damage may result.
• If the mechanical components of the devise are not protected by the casing and fall, irreversible damage of the
ventilation system and certain electrical components may result.
• Modifications made to the casing (and in particular if holes are bored), may result in the deposit of metallic shavings
or filings onto the electronic card and consequently may cause the malfunction of or damage to the device.
• Interfering with or modifications made to the electronic card may result in unforeseen operations and consequently
may cause the malfunction of or damage to the device.
• Use of a non-adapted power supply (as a general rule, the input voltage will be too high) may cause the malfunction
of or damage to the device.
• An accidental electrical surcharge or lightening strike will generally cause the malfunction of or damage to the
device.
• Replacement of battery fuses with fuse types other than those recommended (same characteristics) may cause the
malfunction of or damage to the device.
• Obvious connection errors will result in the malfunction of or damage to the device.
• Water or condensation gaining access to the interior of the device may cause its malfunction or damage it.
Battery Cables
12V 30A
6mm² (0.093in²)
1.5m (4.92')
Fuses
12V 30A
T8A-250V
2 x F20A -32V
Output Cable
For distribution output, we recommend you use a HO7RNF cable.
12V 30A
3 x 2.5mm² (0.04in²)
5m (16.5')
Warranty
Page 8
12V 40A
10mm² (0.155in²)
1.5m (4.92')
12V 40A
T10A-250V
2 x F30A-32V
12V 40A
3 x 2.5mm² (0.04in²)
3 x 2.5mm² (0.04in²)
5m (16.5')
24V 20A
6mm² (0.093in²)
1.5m (4.92')
24V 20A
T10A-250V
F30A-32V
24V 20A
5m (16.5')