Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 1 reaches the
mechanical stop.
8. The board will automatically exit the programming menu and will display the status of the automated
00
system (
) as confirmation that the SET-UP procedure has been completed correctly. If the
procedure is not completed correctly,
SET-UP procedure must be performed.
The deceleration spaces can be configured and modified from the
parameters on the display (refer to Advanced Programming) without having to
repeat the SET-UP.
Refer to the complete instructions if there are limit switches.
5.
USEFUL PARAMETERS TO PROTECT AGAINST THE RISK OF IMPACT/
CRUSHING ON THE MAIN EDGE
PARAMETER
FUNCTION
Allows the static thrust force of motor 1 to be adjusted.
F1
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
Allows the static thrust force of motor 2 to be adjusted.
F2
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
Enables the encoders to be read by the electronic board, thereby guaranteeing
En
that inversion occurs in the presence of obstacles (set
Allows the closing delay of motor 1 to be modified in order to obtain a phase shift
Cd
between the two leaves and reducing the risk of crushing between the two moving
leaves.
Allows the space of reduced speed of leaf 1 to be adapted. The impact at slow
r1
speed allows the dynamic force to be reduced.
Allows the space of reduced speed of leaf 2 to be adapted. The impact at slow
r2
speed allows the dynamic force to be reduced.
EC
Allows the obstacle inversion sensitivity to be adjusted.
Allows the space before the mechanical stops in which the board does not per-
rB
form inversions to be modified (set a value between 1 and 49 mm).

6. OPERATING LOGIC

This table summarises the operating logic.
Refer to the complete instructions for a detailed description of each.
Status of the automated
LOGIC
E Semi-automatic
An OPEN pulse opens the
gate and the following one
closes it
E145
S0
will start flashing on the display, indicating that a new
Status of the automated
system:
stopped
An OPEN pulse stops the
gate when opening and
reopens when the gate is
closing
Operation WITH Encoder
Leaf 1 will stop as soon as it reaches the me-
chanical stop. If there is no mechanical stop,
stop the leaf movement at the desired point by
sending an OPEN A pulse.
system:
in motion
The photocells invert during motion
9
r1
r2
and
EN
Y
).
=
Status:
photocell action
732783 - Rev.C

Publicidad