Airwell RWV05 Manual De Operación E Instalación página 20

Mando por cable
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
Operation
Mode Setting (Only valid for part of models)
(1) In off and non screen saving state, press Mode key for 5s, it will display 8 segment on the top-left
corner of current mode circulation, default value being 0. Press Up/Down key to shift between 0, 1, 2, 3,
then press Set key to confirm value. It will follow the altered mode circulation after turning on the unit
again.
Corresponding mode of different value.
0-------------[Intelligent] [Heating] [Dry] [Cooling] [Fan] 1-------------[Heating] [Dry] [Cooling] [Fan]
2-------------[Dry] [Cooling] [Fan]
3-------------[Heating] [Dry] [Cooling] [Fan]
(2) The intersection of mode circulation set by wired controller and indoor unit is valid.
(3) Fresh Air unit can execute mode setting, it will execute the intersection with three modes of Fresh
Air unit (cooling/heating/fan mode)
(4) The mode of indoor units can be inquired /changed by the advanced setting function after the wired
controller is powered on, Only valid for part of models.
(5) Set as follows (Only valid for part of models):
Press Set key and Up key for 5s to enter the advanced setting state, with the function A in temp.
display area displayed statically. Press Fan key to switch to function B. The function code 01 displayed
in the clock display area will flash. The specific information in the timing display area is statically
displayed, it can be changed in the range of 00-03 by Up/Down key. At this time press Set key to
confirm, and the function code 01 in clock display area stays static, the specific information in the
timing display area flashes, meaning it can be changed currently. Press Up/Down key to change the
content and Set key to confirm.
17

Publicidad

Tabla de contenido
loading

Tabla de contenido