Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL HOOD

Hang hood from (4) Mounting Screws (from parts bag).
1
Slide hood towards wall until mounting screws are engaged
in narrow end of (4) Keyholes. Tighten mounting screws
securely.
CAUTION
DO NOT PUSH ON FAN BLADE. Pushing on the
blade may cause it to interfere with other hood parts.
Connect ductwork to hood. Use Duct Tape to make joints
2
secure and air tight.
3
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2)
R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
CAUTION:
!
Bulbs may be hot! Refer to bulb packaging
for further information.
4
Remove plastic protective film from outer frame of filters.
5
Replace filters and make sure fan blade turns freely. Turn on
power at service panel, and test for proper operation.
OPERATION
Fan and Lights: 3 push button switches for each. Push any but-
KEYHOLE
ton to select one of 3 fan speeds or one of 3 light levels. Push the
(4)
same button to turn fan or light off. Press another button to change
fan speed or light level. A light above each fan button indicates the
fan speed.
Heat Sentry: Your range hood is equipped with the Heat Sentry
MOUNTING
feature, which monitors temperature. The Heat Sentry will automati-
SCREW
cally turn the fan on at its highest speed when the temperature is
(4)
above normal.
1) If a fan setting is selected when the Heat Sentry in on, the light
above the fan button will flash on and off.
2) If the fan setting is off when the Heat Sentry is on, the light above
fan button 3 will flash on and off rapidly.
After the temperature has lowered to normal, the fan will change to
the setting prior to the Heat Sentry turning on.
Fuse: The hood control contains a fuse to protect it from power
surges. If the fuse has opened (blown), the green fan-level indicators
DUCT
will operate properly when the fan buttons/switches are pressed - but
TAPE
the fan and lights will not turn on.
The fuse is a 5 x 20 mm, 10 Amp, Fast-Acting, 125V (min.). Common
manufacturer and part numbers are: Littlefuse, 217010; Bussmann,
GMA10A; Wickmann, 1942100. Radio Shack, Digikey (1-800-344-
4539), and most electronic supply stores have them in stock.
To replace the fuse:
1.
2. Remove filters, bottom panel, light wire harness, and air chute.
3. Remove and inspect fuse. If it is not open (blown), additional
4. Install new fuse.
5. Re-assemble air chute, light wire harness, bottom panel, and
PAR20,
6. Turn on power and check hood/control operation.
50W MAX.
HALOGEN
NOTE:
BULB (2)
This hood utilizes an offset blower design to achieve greater
- or -
performance and lower sound levels. As a result, you may notice
R16,
that cooking impurities are more attracted to one side or appear
40W MAX.
to be pulled-in faster than they appear on the opposite side. This
INCANDESCENT
is completely normal. The hood has been designed and tested to
BULB (2)
provide good capture of cooking impurities and odors under all
normal cooking conditions regardless of the cooking location on the
cooktop. Please note that cooking on the rear burners will always
result in the best capture results, regardless of the hood design.
ALLURE™ WS15 SERIES
Disconnect power at service entrance.
diagnostics need to be done.
filters.
RANGE HOOD
Page 5

Publicidad

Tabla de contenido
loading

Tabla de contenido