Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

ALLURE
WS15 SERIES
RANGE HOODS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent backdraft-
ing. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection As-
sociation (NFPA), and the American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range hood
with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10.This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low
or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of
the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam
explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
FOR DOMESTIC COOKING ONLY
!
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
4. For best capture of cooking impurities, your range hood should be
mounted so that the top of the hood is 24-30" above the cooking surface.
5. Please read specification label on product for further information and
requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 5.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"PREPARE HOOD LOCATION"
Run ductwork from roof or wall cap, and electrical wiring from service
panel - to installation location
"PREPARE THE HOOD"
Get your hood ready for installation
"CONNECT WIRING"
Make electrical wiring connections to hood
"INSTALL HOOD"
Secure hood to cabinet and ductwork - install bulbs and filters
"OPERATION"
How to use the hood controls
"CLEANING"
Keep your hood in top working condition
"SERVICE PARTS"
Part numbers and exploded view of hood components
"WARRANTY"
One-year limited warranty and how to contact us
Register your product online at: www.nutone.com/register
ALLURE™ WS15 SERIES
RANGE HOOD
Patent No.:
US D450, 829 S
!
Page 1
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone ALLURE WS15 Serie

  • Página 1 RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* “INSTALL HOOD” 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, Secure hood to cabinet and ductwork - install bulbs and filters then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE “OPERATION” DEPARTMENT. How to use the hood controls 2. NEVER PICK UP A FLAMING PAN — You may be burned. “CLEANING” 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam Keep your hood in top working condition explosion will result. 4. Use an extinguisher ONLY if: “SERVICE PARTS” A. You know you have a Class ABC extinguisher and you already know Part numbers and exploded view of hood components how to operate it. “WARRANTY” B. The fire is small and contained in the area where it started. One-year limited warranty and how to contact us C. The fire department is being called. D. You can fight the fire with your back to an exit. Register your product online at: www.nutone.com/register * Based on “Kitchen Fire Safety Tips” published by NFPA.
  • Página 2: Prepare The Hood

    ALLURE™ WS15 SERIES RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE HOOD LOCATION ROOF CAP 3¼" X 10" 3¼” x 10” or 7” ROUND (For vertical 7” ROUND DUCT VERTICAL DUCTING (For vertical discharge) discharge) " " 15 / 16 15 / 16 SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP HOOD...
  • Página 3 ALLURE™ WS15 SERIES RANGE HOOD Page 3 PREPARE THE HOOD PREPARE THE HOOD AIR CHUTE Remove Damper/Duct Connector from inside the hood. Set connec- Remove Air tor aside - with Chute - held in mounting screws place with one and parts bag. (1) screw. DAMPER/DUCT NOTE: Be care- CONNECTOR ful not to discon- nect any wires. Remove Wir- ing Cover from inside the hood. Remove Baffle Set cover and from air chute.
  • Página 4: Connect Wiring

    ALLURE™ WS15 SERIES RANGE HOOD Page 4 PREPARE THE HOOD CONNECT WIRING TOP RECTANGULAR WARNING: To reduce the risk of electric shock, DUCT KNOCKOUT make sure power is switched off at the service SEMI-CIRCULAR (Remove for 3¼” x 10” panel. Lock or tag service panel to prevent power DUCT KNOCKOUT Vertical &...
  • Página 5: Install Hood

    ALLURE™ WS15 SERIES RANGE HOOD Page 5 INSTALL HOOD OPERATION Fan and Lights: 3 push button switches for each. Push any but- KEYHOLE ton to select one of 3 fan speeds or one of 3 light levels. Push the same button to turn fan or light off. Press another button to change fan speed or light level. A light above each fan button indicates the fan speed. Heat Sentry: Your range hood is equipped with the Heat Sentry MOUNTING feature, which monitors temperature. The Heat Sentry will automati- SCREW cally turn the fan on at its highest speed when the temperature is above normal. 1) If a fan setting is selected when the Heat Sentry in on, the light Hang hood from (4) Mounting Screws (from parts bag). above the fan button will flash on and off. Slide hood towards wall until mounting screws are engaged 2) If the fan setting is off when the Heat Sentry is on, the light above in narrow end of (4) Keyholes. Tighten mounting screws fan button 3 will flash on and off rapidly.
  • Página 6: Service Parts

    This warranty supersedes all prior warranties. R564074 Control Fuse, 10A To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature Order replacement parts by PART NO. - not by KEY NO.
  • Página 7 “OPERACIÓN” 2. NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS - Usted se Cómo usar los controles de la campana podrá quemar. “LIMPIEZA” 3. NO UTILICE AGUA, incluyendo toallas de cocina mojadas - puede resultar una explosión de vapor violenta. Mantenga su campana en condiciones óptimas de funcionamiento 4. Utilice un extinguidor SOLAMENTE si: “PIEZAS DE REPUESTO” A. Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar. Número de las piezas y vista ampliada de los componentes de la campana B. El incendio es pequeño y contenido dentro del área donde se inició. C. Los bomberos han sido avisados. “GARANTÍA” D. Usted puede combatir el incendio con una salida a su espalda. Garantía limitada de un año y cómo comunicarse con nosotros * Basado en las recomendaciones para “Seguridad en la Cocina” publicadas por la NFPA de los EEUU. Registre su producto en línea en: www.nutone.com/register...
  • Página 8: Preparación Del Lugar Donde Se Va A Instalar La Campana

    ALLURE™ WS15 SERIES CAMPANA EXTRACTORA SERIE WS15 ALLURE™ RANGE HOOD Página 8 Page 8 PREPARACIÓN DEL LUGAR DONDE PREPARACIÓN DEL LUGAR DONDE SE VA A INSTALAR LA CAMPANA SE VA A INSTALAR LA CAMPANA TAPA DE TECHO CONDUCTO DE SISTEMA VERTICAL DE CONDUCTOS 8,3 cm x 25,4 cm O REDONDO DE 17,8 cm REDONDOS DE 17.8 CM (7”)
  • Página 9 ALLURE™ WS15 SERIES CAMPANA EXTRACTORA SERIE WS15 ALLURE™ RANGE HOOD Página 9 Page 9 PREPARACIÓN DE LA CAMPANA PREPARACIÓN DE LA CAMPANA Quite el conector CONDUCTO del regulador de PARA AIRE tiro/conector del Quite el con- interior de la cam- ducto para aire pana. Ponga aparte - fijado con un el conector, con los (1) tornillo. tornillos de montaje y la bolsa de piezas. NOTA: Tenga cuidado de no desconectar CONECTOR DEL REGULADOR...
  • Página 10: Conexión Eléctrica

    ALLURE™ WS15 SERIES CAMPANA EXTRACTORA SERIE WS15 ALLURE™ RANGE HOOD Page 10 Página 10 PREPARACIÓN DE LA CAMPANA CONEXIÓN ELÉCTRICA ADVERTENCIA: Para reducir el riesgo de descar- AGUJERO CIEGO PARA CONDUCTO SEMI- gas eléctricas, asegúrese de apagar el interruptor AGUJERO CIEGO SUPERIOR DEL CIRCULAR CONDUCTO RECTANGULAR de alimentación eléctrica en el panel de servicio. (Quite en el caso de (Quite en el caso de descargas verti- Bloquee o rotule el panel de servicio para evitar...
  • Página 11: Instalación De La Campana

    ALLURE™ WS15 SERIES CAMPANA EXTRACTORA SERIE WS15 ALLURE™ RANGE HOOD Página 11 Page 11 INSTALACIÓN DE LA CAMPANA OPERATION ORIFICIO TIPO BOCALLAVE Ventilador y luces: 3 conmutadores de pulsadores para cada uno. Presione cualquier pulsador para seleccionar una de las tres veloci- dades del ventilador o una de las tres intensidades de luz. Presione el mismo pulsador para apagar el ventilador o la luz. Presione otro pulsador para cambiar la velocidad del ventilador o la intensidad de TORNILLO la luz. Una luz verde que se encuentra sobre cada pulsador indica la velocidad del ventilador. MONTAJE Heat Sentry: La campana de su estufa está equipada con la caracte- rística Heat Sentry que supervisa y controla la temperatura. Cuando Cuelgue la campana de los (4) orificios de montaje (que se la temperatura sea mayor que la normal, la característica Heat Sentry encuentran en la bolsa de piezas). Deslice la campana hacia encenderá automáticamente el ventilador a la velocidad más alta.
  • Página 12: Limpieza

    R564074 Fusible de control, 10A Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono que se menciona abajo, (b) dar el número del modelo y la identificación Pida piezas de repuesto dando como referencia el Nº. DE PIEZA, no el Nº. DE CLAVE de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza.

Tabla de contenido