INTRODUCTION:
Whirlpool baths must be installed by trained personnel able
to demonstrate to the relevant authorities their knowledge
and ability in the application of health and safety regulations,
i.e. electricity and water supplies and waste water disposal. The
manufacturer provides training for technical assistance staff and
therefore you are advised to contact an authorised technical
assistance centre for the purposes of installation.
This symbol is used throughout this manual to indicate
important instructions or important safety information
about the product.
INSTALLATION:
IMPORTANT!
IMPORTANT!
Before starting to assemble and install the product, carefully
read through all the instructions. Unpack the components and
check that nothing is missing and that there are no damaged
or faulty components; remove the transparent protective film,
where present.
All components requiring maintenance (e.g. pump, electrical
components, etc.) must remain accessible once the final
installation is complete.
Do not use the hoses to support the bath during transport.
N.B.: This product is designed for installation on finished walls
and floors.
For all warranty claims, the purchase invoice/receipt must be
produced along with the product assembly instructions.
The drawings and illustrations in this manual are provided for
information purposes only.
The manufacturer reserves the right to make changes and
improvements.
INSTALLATION OF BATH WITH FRAME:
Follow the sequence of drawings given in this manual very
carefully when installing a bath with frame.
INSTALLATION OF ENCLOSED BATH:
Before building the enclosing walls, it is best to position the
bath and make the required connections. The wall can extend
inwards under the lip of the bath by not more than 1.5 cm. The
drain must be connected in such a way that the bath can be
pulled out of the enclosure for maintenance, when necessary.
To facilitate this operation, do NOT fix enclosed type baths to
the floor. In this case, fix the bath by applying silicone on all four
sides (see siliconing illustration on page 45).
Inspection panel required.
FITTINGS (optional):
A pack of finishing profiles can be ordered on request, which are
easy to install and make the joint between the wall and the edge
of the bath both aesthetically elegant and functional (please
contact your retailer). These profiles are suitable for use on baths
of any size.
(I)
OPERATING TEST:
An operating test must be performed following installation.
Check that the bath is clean.
Fill the bath with water at an infeed temperature of 40 °C (± 5
°C) up to a level above the highest nozzle to allow the system to
function.Switch on the system and run it for 10 minutes. Switch
OFF the whirlpool function but do not empty the bath and after
10 minutes check all the hoses, couplings, etc. for any leaks.
The test should be repeated following any adjustments or
substitutions.
Backflow of water towards the mains water supply must be
avoided to ensure conformity with EN 1717 when filling the
bath. Therefore if the taps are fitted so that the water fills the
bath from above the top of the bath then the taps must be
positioned (at least in terms of height) in accordance with the
diagrams shown on page 28/35.
If the system involving a combined water inlet and overflow
outlet is used to fill the bath, a water outlet spout consisting of
a non-return valve (not supplied) must be fitted between the
combined tap water inlet point and the delivery system located
on the discharge column.
CLEANING AND DISINFECTING:
During use, small organic particles are deposited in the whirlpool
pipes and if not treated may lead to proliferation of bacteria in
the system. For optimum hygiene, you should treat the system
with specific products available from our Service Centres (see
updated list on our site www.novellini.com under the heading
"Service") or dealers specialising in products for whirlpool baths.
For temporary treatment you can use a liquid disinfectant (e.g.
Dettol).
How to disinfect the bath:
If the bath has an automatic disinfection facility, please refer
to the disinfection menu using the remote control, otherwise
proceed as follows.
Cleaning the bath:
Fill the bath with clean water, to the level used during normal
use. Then add 80 grammes of disinfectant to the water. Set the
whirlpool running for a few minutes so that the disinfectant
circulates throughout all the pipes. Then turn it off, wait for 15-
20 minutes, and empty the bath.
You should also perform a specific treatment if the bath is left
unused for long periods. If the bath is used by more than one
person consecutively, you are recommended to disinfect after
each cycle.
-29-
ENGLISH
1
2
3