INSUFFICIENT WATER PRESSURE

In situations where the water flow from the pump is not powerful enough to purge the
sediment out of the sediment chamber. Jacuzzi recommends fitting a 2 way valve after the
JMC16 on the pool water return line.
The 2 way valve is used to throttle the flow of water out of the JMC16, increasing water
turbulence through the sediment chamber and improving its purging action.
While the pump is operating, open the purge valve, and then partially close the 2 way
valve, throttling the water flow sufficiently to purge the sediment chamber of trapped
sediment. Once the sediment chamber is clean, open the 2 way valve and then close the
purge valve.
Installation with 2 way shut off valve Cartridge Filter
!
Do not close the 2 way valve prior to opening the purge valve and do not close
the purge valve while the 2 way valve is closed or partially closed. Both valves
should never be closed or partially closed at the same time.
If the JMC16 is installed to a media filter, water flow to the media filter can be closed via
the media filter's multiport valve.*