Publicidad

Enlaces rápidos

JCF425 Cartridge Filter System •
JCF425 Serie Filtro de Cartucho
OWNER'S GUIDE • MANUAL DEL USUARIO
INSTALLATION INSTRUCTIONS • INSTRUCCIONES DE INSTALACION
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Jacuzzi JCF425

  • Página 1 JCF425 Cartridge Filter System • JCF425 Serie Filtro de Cartucho OWNER’S GUIDE • MANUAL DEL USUARIO INSTALLATION INSTRUCTIONS • INSTRUCCIONES DE INSTALACION...
  • Página 2: Installation Instructions

    This filter operates under high pressure. Failure to follow instructions may result continuous or intermittent operation, for installation above or below the pool water in serious injury. line, and for fresh or salt water swimming pools or spas. Jacuzzi ® Cartridge Filters Make sure clamp is located properly over the filter flange.
  • Página 3 INCLUDED SIDE-MOUNT MULTI-PORT VALVE - INSTRUCTIONS PIEZAS DE VÁLVULA DE PUERTO MÚLTIPLE DE MONTAJE LATERAL Articulo Descripción Articulo Descripción Manija Lavadora Pin de la manija Etiqueta Cubrir Junta tórica Tornillo Junta tórica Nuez El tapón Lavadora Junta tórica Desviador Resorte Junta de estrella Vista el vidrio La cubierta...
  • Página 4 Espacio libre superior Espacio libre lateral Model No. Modelo N° JCF425 PUMP SELECTION AND LOCATION: FILTER LOCATION: To power your filter, select a continuous duty pump designed for swimming pool or spa Since plumbing fittings offer a resistance to water flow, position the filter as close to the service.
  • Página 5 Ball Valve Válvula de bola Gate Valve Válvula de compuerta PLUMBING: Ball or gate valves are recommended where needed. While all systems vary, the main Use 1 1/2", 2" or 2 1/2" piping. Connections are 2" slip (solvent weld). consideration is to provide the desired control of water flow from the pool to the pump, to the filter and back to the pool.
  • Página 6 CAUTION: ANSI/ NSPI-4 Article V, standard for in-ground pools, advises All electrical connections should be made in accordance with local codes. that components such as the filtration system, pumps and heater be positioned so as to prevent access by young children. PRECAUCION: El articulo V de ANSI/NSPI-4 para piscinas bajo tierra, Todas las conecciones electricas deben realizarse segun las normas locales.
  • Página 7 8-10 PSI 8 a10 LPPC (55,15 kPa a 68,94 kPa) + 8-10 PSI Filter Pool Time to Service Adjust Service Dial Ajustar cuadrante de servicio +8 a 10 LPPC Filtro Piscina (+55,15 kPa a 68,94 kPa) Registro de servicio Above Start (Clean) Pressure Por encima de la presión de inicio (limpia) 11.
  • Página 8 14. DISASSEMBLY: Shut off the pump then use a 7/8” deep socket and ratchet (1) to remove Spring Barrel. Place clamp assembly out of the way in a convenient place (2). You can now easily remove the filter lid, exposing the dirty element assembly. Damage to clamp may lead to system failure.
  • Página 9 17. You may find some debris on the cartridge pleats, which may have not been removed with hosing. In such a case, soak the cartridge in a solution of filter element cleaner (found at pool dealers). Follow manufacturer’s directions for use. Hose thoroughly before reinstalling the cartridge in the filter.
  • Página 10 Filter Pool Filtro Piscina Important: Be sure to tighten nut until spring coils Drain Plug touch each other. Importante: Asegúrese de apretar la tuerca hasta Tapón de drenaje que los espirales del resorte se toquen entre sí. Spring Barrel Conjunto de tuerca y Nut Assembly resorte cilíndrico sobre on Threaded T-Bolt...
  • Página 11: Informacion Importante

    Consulte a su negocio o centro de reparacion local autorizado por Jacuzzi Inc. Devoluciones no directly to the factory without the expressed written authorization of Jacuzzi Inc. se haran directamente a la fabrica sin antes tener la autorizacion por escrito de Jacuzzi Inc.
  • Página 12 INSTALLING BODY O-RING INSTALACION DE EMPAQUE Clean and lube O-Ring before installing. Limpie el empaque antes de instalar. IMPORTANT NOTE: NOTA IMPORTANTE: O-Ring will climb off if twisted. El empaque subira si esta torcido. Start at back (opposite side from fittings), place O-Ring around lip of filter and Slide hands back to you, making sure O-Ring does not twist.
  • Página 13 BULKHEAD GASKET INSTRUCCIONES PARA INSTALLATION LA INSTALACIÓN DE INSTRUCTIONS UNA JUNTA DE ACOPLE 415-4211 419-4201 Union Nut 417-2201 Bulkhead Fitting Tuerca de unión Tailpiece Accesorio de acople Alcachofa de aspiración 711-4200 805-0232 Gasket O-Rings Junta Juntas tóricas Insert the Gasket (711-4200) with beveled edge facing in, inside each Bulkhead Fitting (2) (419-4201). Apply a non-petroleum lubricant to O-Rings (805-0232) on Tailpiece (417-2201).
  • Página 14: Replacement Parts Diagram

    805-0233 O-Ring (2) 827-8150 Filter Internal Spring 519-4370 Plunger 718-4200 Valve Nut 519-4219-BEI 425 sq. ft. Filter Lid with Cartridge Jacuzzi ® Filter Labels 550-4260 Metal Clamp with Clamp Spring Assembly 550-4550 Clamp Spring Assembly 805-0000 O-Ring Main Body 519-4320...
  • Página 15: Remplazos Para El Filtro De Cartucho

    Pistón 718-4200 Tuerca de la válvula 519-4219-BEI Tapa del filtro de 425 pies cuadrados (395cm ) con etiquetas del filtro de cartuchos Jacuzzi ® 550-4260 Abrazadera metálica con conjunto de abrazadera de resorte 550-4550 Conjunto de la abrazadera de resorte 805-0000 Cuerpo principal de la junta tórica...
  • Página 16 POR ENCIMA GPM* PSI** MODEL / MODELOS JCF425 39.5 3.45 MAXIMUM HEAD LOSS @ 150 GPM IS 4.1 PSI • LA PÉRDIDA PRINCIPAL MÁXIMA @ 150 GPM ES 4.1 PSI * 1 GPM = 0.063 l/s or liters per second ** 1 PSI = 6.8948 kPa or kilopascals...

Tabla de contenido