English
WINTERIZING
Proper procedures should always be taken in order to protect your filter in cold
climates (temperatures below freezing point).
1. Switch off the Pump / Close the inlet valve.
2. Open the air release valve and open the purge valve to allow water to flow out of
the JMC16.
a. Media Filter, move the Multi Port Valve handle to the winterize position
(between filter and waste).
b. Cartridge Filter, open air release valve. This will allow air to through to all ports.
3. Remove any drain plugs from the pump.
4. Drain water from the pipe work.
JMC16
| pg 16