NOTE:
There are 11 levels of predefined scales : Auto, 300 m, 1.3 Km, 2.5 Km,
5 Km, 10 Km, 20 Km, 40 Km, 80 Km, 160 Km and 240 Km.
«Auto» means the automatic measurement. When this function is selected,
the instrument will automatically make an intelligent selection of adequate
range and pulse width for measurement. The whole process of measurement
does not need any intervention of the operator.
«Auto» means the default settings.
•
Pulse Width Configuration
The selection of pulse width affects the dynamic range and resolution of
measurement trace. With narrow pulse width, there will be higher resolution and smaller
dead zone, however, the dynamic range will be decreased. On the contrary, wide pulse
width can bring higher dynamic range and measure comparatively long distance, but
resolution and dead zone will be affected. Therefore, users should make choice
between dynamic range and dead zone.
There will be different pulse width options for reference according to different
range of distance being chosen.
Under menu of parameter configuration, use [
] to select as shown in Figure 16.-. Press [
width"; Press [
Page 24
Figure 15.- Range Configuration.
USER'S MANUAL. PROLITE-50/51/52
] and [
] to highlight "pulse
] to exit.
11-2015