Nice TT1VR Instrucciones Y Advertencias Para La Instalación Y El Uso página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
✔ Response with sunshine (intermediate position, Venetian
position or bottom limit).
✔ Response without sunshine (intermediate position, Vene-
tian position, top limit or no movement).
✔ In case of wind, the Venetian blind may receive transmit-
ter commands.
✔ The automatic response to climate sensor signals can
be disabled with the AUTO-ON / AUTO-OFF control of
the ERA P transmitter.
• MEMORY
✔ Lock memory: this setting prevents further transmitters
from being memorized.
• DELETIONS
✔ Delete all: restores the TT1VR's factory settings.
✔ Delete transmitters.
✔ Delete a single transmitter.
✔ Delete positions.
✔ Delete with NON-memorized transmitter.
• SLIDER
✔ Possibility of using the slider:
- with Venetian blind mode active, the slider allows for
performing tilting (in this mode the Venetian blind moves
in jerks);
- with mechanical motor mode active, if the slider is
pressed in the 0% point it brings the blind/shutter to the
Low limit switch; if pushed in the 100% point, it brings
the blind/shutter to the High limit switch; if, instead, it
is pressed in the 10, 20, 30, 40, 50, 60, 70, 80, 90%
points, it brings the blind/shutter to the corresponding
partial levels.
4
PROGRAMMING
TT1VR programming, must be done ONLY with "ERA P"
transmitters: the PRG and ESC keys are required.
These keys are positioned on the back of the transmitter
under a cover plate, to prevent unintentional programming.
4.1 - Programming the FIRST transmitter
by acquisition in Mode 1
This programming automatically memorises all the keys:
command n.1 is automatically mapped to key 1, command
2 to key 2, etc. (depending on the number of keys on the
transmitter).
Tables 1 and 2 describe the available commands:
2 – English
• Commands available with tilting mode ENABLED
(ideal for Venetian blinds)
TABLE 1
COMMAND DESCRIPTION
▲ (brief)
The blind moves to its top limit position
▼ (brief)
The blind moves to its bottom limit position
▲ (2 s)
Venetian blind tilting upwards
▼ (2 s)
Venetian blind tilting downwards
Stop
The blind moves to the Venetian position
▲ + ▼
(if set)
The blind moves to intermediate position
▲ + ■
1 (if set)
• Commands available with tilting mode DISABLED
(ideal for shutters and awnings)
TABLE 2
COMMAND DESCRIPTION
The shutter/awning moves to its top limit
position
The shutter/awning moves to its bottom
limit position
Stop
The shutter/awning moves to intermedi-
▲ + ▼
ate position 1 (if set)
The shutter/awning moves to intermedi-
▲ + ■
ate position 2 (if set)
4.1.1 - Mode 1 programming procedure
01.
ON
ters are memorised,
2
2 movements are
available
02.
= 10 sec
PRG
PRG
4.2 - Programming Venetian Position
Hight limit
switch
Low limit
switch
4.2.1 - Programming procedure Venetian position
01.
02.
= 3 sec
03.
the venetian reach automatically the
bottom limit position
04.
to reach the
venetian
position
05.
to save the position
= 3 sec
- 6 movements if the procedure was not successfully
If no transmit-
completed
4.3 - Memorising an additional transmit-
ter o climate sensor
4.3.1 - Programming with a transmitter without
PRG key
3
This programming memorises transmitters which do not
have the PRG and ESC keys as well as older transmitters
(in the description of the programming procedure, "N" is
the number of presses for the key to be mapped to the
Venetian
position
PRG
2
3
3

Publicidad

Tabla de contenido