6
• Before each use inspect the gas hose to
ensure it is free of any twisting or tension
User Instructions
KLASEN side burner is only to be used
together with KLASEN gas barbecue.
Before assembling your side burner, remove
all protective packaging from each part.
Do not store a spare LP gas cylinder under or
near this appliance.
Cylinder used must include a collar to protect
the cylinder valve
Never fill the cylinder beyond 80% full. Failure
to follow these instructions exactly may result
in fire causing serious injury or death.
Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only
install the type of dust cap on the cylinder
valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result
in leakage of propane.
The gas cylinder must have a connection
compatible with regulator supplied with the
barbecue and have a minimum capacity of
4kgs/9lbs.
SIDE BURNER USER INSTRUCTIONS
Before proceeding, make certain that you
understand the WARNING statements in this
manual.
BEFORE USING THIS APPLIANCE:
1. Please read all of these instructions
and appliance owners manual prior to
installation and use.
2. FOR OUTDOOR USE ONLY!
• Appliance and tank must be in open,
well ventilated outdoor area prior to
connection end use. Make sure the tank
valve is fully closed and not leaking prior
to moving or connecting.
• NEVER USE IN A GARAGE OR UNDER
OVERHANGS!
• NEVER STORE A SPARE CYLINDER OR
ANY FLAMMABLE
• LIQUID OR GAS UNDER OR NEAR THIS
APPLIANCE OR
• ANY OTHER HEAT SOURCE.
3. Be sure tank valve and regulator are
proper mating types, with correct
threads or fittings, see manual.
4. Inspect tank valve, regulator, hose and
fittings to be sure they are clean, free
or dirt, debris, not plugged and not
damaged. If damaged replace before
use. See local LP dealer for repairs.
5. Prior to connection, turn all control
valves to the OFF position.
6. Connect regulator to tank valve
according to appliance owners manual.
Handle cylinder with care – the contents
are under high pressure.
7. If good connection has been made,
slowly open tank valve to full open. Use
a soapy water solution to check all gas
connections for leaks before lighting
appliance.
• NEVER TEST WITH OPEN FLAME!
• IF YOU SMELL GAS OR A LEAK IS FOUND:
— SHUT OFF GAS AT THE TANK VALVE
IMMEDIATELY.
— EXTINGUISH ANY OPEN FLAME, OR
OTHER POTENTIAL IGNITION SOURCE.
— DO NOT USE APPLIANCE UNTIL REPAIRS
ARE MADE BY QUALIFIED LP GAS
DEALER.
— DO NOT ATTEMPT TO MAKE REPAIRS
YOURSELF!
— DO NOT USE ANY APPLIANCE, OR
PARTS, EXPOSED TO OR DAMAGED BY
FIRE!
8. If not leaking, carefully light appliance
and use according to the instructions in
this manual. This appliance regulator
and tank valve connection may contain
two or more important safety features
such as Excess Flow Control and High
Temperature Activated Shutoff.
• FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN AN
EXPLOSION OR FIRE THAT MAY CAUSE
PROPERTY DAMAGE, SERIOUS INJURY OR
DEATH!
• NEVER LEAVE THIS APPLIANCE
UNATTENDED WHILE IN USE! NOT TO BE
USED BY CHILDREN!
Lighting the Side burner
• Open the side burner lid.
• Ensure control knob is in the 'OFF'
position.
• Turn on the gas supply at the gas cylinder.