18
en
SG 200 Acoustic Signaling Device
Installation
1.
The upper part of the signaling device is connected to
the base by a bayonet lock.
2.
The upper part of the signaling device is also secured against
unintentional removal by a screw.
3.
The pre-punched openings on the mounting base for the fastening
screws and cable feeds must be broken out or drilled through.
4.
Connect the mounting base and signaling device with the enclosed
screws.
5.
When connecting to monitored control lines with acknowledgement,
the signaling device must be operated using a UAR universal connection
relay.
6.
When connecting to monitored control lines without acknowledgement,
a UAR is not necessary.
7.
With a selected tone type, on activation of the second input, the second
tone type (in parentheses) is switched on.
8.
Doubled screw clips to loop through voltage.
Figure 1 Tone type 6, code 00101
1
DIP switch
2
Volume control
F.01U.029.058 | A3 | 2007.12
1
1
2
1
0
nd
2
Tone
st
1
Tone
-
nd
2
Tone
st
1
Tone
12-24 V DC
3
4
5
nd
2
Tone
-
-
-
+
3
Connection terminals
2
st
1
Tone
3
+
Bosch Security Systems
SG 200