The shutter kit is used to control five shutters typically distributed in different rooms.
It allows to control each shutter locally in addition to providing eight different opening/closing scenarios
from two specific positions.
USe
We will call the five shutters S0, S1, S2, S3 and S4 for the sake of simplicity.
Each shutter can be operated locally by means of two buttons or a double button (not necessary interlocked).
In all cases, one button will be used for opening and the other for closing.
Two specific positions are available which can be made using three or four buttons or three or four double
buttons (not necessarily interlocked). The operation will be as follows, according to the installed buttons.
Simple buttons
In Room A (and/or B), 3 or 4 buttons (P1..P4), grouped on the same plate open a set of shutters when
pressed briefly. They close the same set of shutters if pressed for longer than one second:
P1, Open/Close S0,S1
P2, Open/Close S0,S1,S2
P3, Open/Close S3,S4
P4, Open/Close S0,S1,S2,S3,S4.
Double buttons (not necessarily interlocked).
In Room A (and/or B), 6 or 8 buttons (P1..P8), grouped on the same plate, directly control - if pressed briefly
- the opening or closing of a set of shutters:
P1, Open S0,S1
P2, Open S0,S1,S2
P3, Open S3,S4
P4, Open S0,S1,S2,S3,S4
P5, Close S0,S1
P6, Close S0,S1,S2
P7, Close S3,S4
P8, Close S0,S1,S2,S3,S4